Impact of 4D-Flow CMR Parameters on Functional Evaluation of Fontan Circulation.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ait Ali Lamia, Martini Nicola, Listo Elisa, Valenti Elisa, Sotelo Julio, Salvadori Stefano, Passino Claudio, Monteleone Angelo, Stagnaro Nicola, Trocchio Gianluca, Marrone Chiara, Raimondi Francesca, Catapano Giosuè, Festa Pierluigi

Аннотация

We sought to evaluate the potential clinical role of 4D-flow cardiac magnetic resonance (CMR)-derived energetics and flow parameters in a cohort of patients' post-Fontan palliation. In patients with Fontan circulation who underwent 4D-Flow CMR, streamlines distribution was evaluated, as well a 4D-flow CMR-derived energetics parameters as kinetic energy (KE) and energy loss (EL) normalized by volume. EL/KE index as a marker of flow efficiency was also calculated. Cardiopulmonary exercise test (CPET) was also performed in a subgroup of patients. The population study included 55 patients (mean age 22 ± 11 years). The analysis of the streamlines revealed a preferential distribution of the right superior vena cava flow for the right pulmonary artery (62.5 ± 35.4%) and a mild preferential flow for the left pulmonary artery (52.3 ± 40.6%) of the inferior vena cave-pulmonary arteries (IVC-PA) conduit. Patients with heart failure (HF) presented lower IVC/PA-conduit flow (0.75 ± 0.5 vs 1.3 ± 0.5 l/min/m2, p = 0.004) and a higher mean flow-jet angle of the IVC-PA conduit (39.2 ± 22.8 vs 15.2 ± 8.9, p < 0.001) than the remaining patients. EL/KE index correlates inversely with VO2/kg/min: R: - 0.45, p = 0.01 peak, minute ventilation (VE) R: - 0.466, p < 0.01, maximal voluntary ventilation: R:0.44, p = 0.001 and positively with the physiological dead space to the tidal volume ratio (VD/VT) peak: R: 0.58, p < 0.01. From our data, lower blood flow in IVC/PA conduit and eccentric flow was associated with HF whereas higher EL/KE index was associated with reduced functional capacity and impaired lung function. Larger studies are needed to confirm our results and to further improve the prognostic role of the 4D-Flow CMR in this challenging population.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты