DOI 10.1097/ijg.0b013e3181d1d348

Медицинская библиотека · Journal of glaucoma · 2011

A new 6 o'clock traction suture technique for glaucoma filtration surgery.

Grehn Franz, Klink Thomas

СтатьяПеревод в очереди

Аннотация

PURPOSE: Recent studies show that using a traction suture through the superior rectus muscle in filtering glaucoma surgery is associated with a lower success rate compared with a corneal traction suture. A 12 o'clock corneal traction suture combined with a fornix-based approach may distort the architecture of the scleral flap.

METHODS

In a new technique, a corneal 6 o'clock traction suture is placed near the limbus, thus avoiding any disturbance at the site of filtering surgery. The suture is passed underneath a notched solid-bladed lid speculum that pushes the suture deep into the inferior fornix and rotates the eye downward.

RESULTS

In 20% a hemostat was needed to fix the suture to the surgical drape. During a period of 26 months and 412 trabeculectomies only 1 corneal perforation in an adult patient with congenital glaucoma and thin cornea was seen.

CONCLUSION

The 6 o'clock traction suture with the glaucoma lid speculum is easy to learn and safe.

Для цитирования: Grehn Franz, Klink Thomas. A new 6 o'clock traction suture technique for glaucoma filtration surgery.. Journal of glaucoma. 2011. DOI: 10.1097/ijg.0b013e3181d1d348.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.