MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.surg.2017.10.049

Медицинская библиотека · Surgery · 2018

Are Foley catheters needed after minimally invasive repair of pectus excavatum?

Friske Tyler C, Sola Richard, Yu Yangyang R, Jamal Abdur R, Rosenfeld Eric, Zhu Huirong, Mazziotti Mark V, St Peter Shawn D, Shah Sohail R

СтатьяПеревод в очереди

Аннотация

BACKGROUND

High narcotic requirements after minimally invasive repair of pectus excavatum (MIRPE) can increase the risk of urinary retention. Placement of intraoperative Foley catheters to minimize this risk is variable. This study determines the rate of urinary retention in this population to guide future practice.

MATERIALS AND

METHODS

We reviewed retrospectively all patients who underwent MIRPE from January 2012 to July 2016 at 2 academic children's hospitals. Data collected included demographics, BMI, severity of the pectus defect, postoperative pain management, and the incidence of urinary retention and urinary tract infection (UTI).

RESULTS

Of 360 total patients who underwent MIRPE, 218 had an intraoperative Foley catheter. Patients with epidural pain control were more likely to receive a Foley catheter. The urinary retention rate was 34% for patients without an intraoperative Foley, and 1% in patients after removal of an intraoperatively placed Foley. Urinary retention was greater with an epidural compared with patient-controlled anesthesia (55% vs 26%, P = .002) in the no intraoperative Foley group. No urinary tract infections were identified. Epidural pain control was the only risk factor on multivariate analysis for retention in patients without an intraoperatively Foley catheter.

CONCLUSION

Intraoperative Foley catheters obviate urinary retention without increasing the risk of urinary tract infection after MIRPE. These results will allow surgeons to better counsel patients regarding Foley placement.

Для цитирования: Friske Tyler C, Sola Richard, Yu Yangyang R, Jamal Abdur R, Rosenfeld Eric, Zhu Huirong, Mazziotti Mark V, St Peter Shawn D, Shah Sohail R. Are Foley catheters needed after minimally invasive repair of pectus excavatum?. Surgery. 2018. DOI: 10.1016/j.surg.2017.10.049.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.