Rapid Magnetic Resonance Imaging of the Spine in Neonates with Spinal Dysraphism.

Khalatbari Hedieh, Perez Francisco A, Lee Amy, Shaw Dennis W W

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The use of nonsedated T2-weighted Half-Fourier Acquisition Single-shot Turbo spin Echo magnetic resonance imaging (MRI) sequences in screening for spinal cord syrinx in neonates with spinal dysraphism has not been reported in the literature. We sought to review our experience using T2-weighted Half-Fourier Acquisition Single-shot Turbo spin Echo imaging of the spine (i.e., rapid spine MRI) in nonsedated neonates for detecting spinal cord syrinx in neonates with spinal dysraphism.

METHODS

We performed a retrospective search of our radiology database for neonates with spinal dysraphism who had rapid spine MRI between May 2017 and February 2020. The images were reviewed in conjunction with clinical findings and standard spine imaging, when available.

RESULTS

Thirty studies (in 29 neonates) fulfilled our inclusion criteria. Of the 26 neonates with myelomeningocele, 5 of them (19%) had spinal cord syrinx identified on neonatal rapid spine MRI. An additional 2 patients developed syrinx by 2 years of age. Potential pitfalls identified in interpreting rapid spine MRI include motion artifacts and distinguishing a severe holocord syrinx from a truncated spinal cord.

CONCLUSIONS

Rapid spine MRI acquired without sedation or anesthesia may be used as a screening technique to detect spinal cord syrinx in neonates with spinal dysraphism.

Для цитирования: Khalatbari Hedieh, Perez Francisco A, Lee Amy, Shaw Dennis W W. Rapid Magnetic Resonance Imaging of the Spine in Neonates with Spinal Dysraphism.. World neurosurgery. 2020. DOI: 10.1016/j.wneu.2020.09.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.