MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Chinese journal of traumatology = Zhonghua chuang shang za zhi · 2007

Application of spiral CT image 3D reconstruction in severe talar neck fracture.

He Fei, Huang He, Deng Ya-min, Wang Bing, Zhang Chun-qiang, Zhao Zhi, Tang Xi-zhang, Zhou Zhao-wen, Zhao Xue-ling

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To explore the application of the spiral computerized tomography (CT) image three-dimensional (3D) reconstruction technique associated with the conventional radiography in the diagnosis and treatment of severe talar neck fracture.

METHODS

Using the multi-slice spiral CT image 3D reconstruction technique, we analysed 11 cases of talar neck fracture. The fractures were reduced and fixed through a minimal incision and internal fixation with titanium cannulated lag screws.

RESULTS

In the 11 cases, the results of CT image 3D reconstruction were in concordance with plain radiograph in 6 case of Hawkins type II. And the remaining 5 cases of Hawkins types III and IV could not be classified exactly only by radiographs, one of whom was misdiagnosed. After using the CT image 3D reconstruction, the 5 cases were classified exactly before osteosynthesis. The classifications of these 11 cases were confirmed finally by surgical findings. The duration of operation were 45-140 min, averaging 81 min (including the duration of C-arm fluoroscopy). X-ray exposure time was 6-58 seconds, averaging 22 seconds. The blood loss was less than 100 ml. The fracture union was achieved in 3 months. No nonunion, talus avascular necrosis or joint surface collapse occurred. Postoperative follow-up was from 1 to 25 months. According to Hawkins score, excellent result was found in 6 type II cases and 1 type III case; good result in 1 type III case with both medial and lateral malleolar fracture, 1 type III with medial malleolus fractures and 1 open type III; fair result in 1 open type IV with lateral malleolus fracture.

CONCLUSIONS

By using the multi-slice spiral CT image 3D reconstruction associated with radiography to diagnose and treat severe talar neck fractures, the accuracy of diagnosis can be improved obviously. Based on this technique, more consummate operational plan can be designed and performed so as to achieve a better therapeutic effect.

Для цитирования: He Fei, Huang He, Deng Ya-min, Wang Bing, Zhang Chun-qiang, Zhao Zhi, Tang Xi-zhang, Zhou Zhao-wen, Zhao Xue-ling. Application of spiral CT image 3D reconstruction in severe talar neck fracture.. Chinese journal of traumatology = Zhonghua chuang shang za zhi. 2007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.