MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arbres.2010.12.011

Медицинская библиотека · Archivos de bronconeumologia · 2011

Reliability of an analysis method for measuring diaphragm excursion by means of direct visualization with videofluoroscopy.

Yi Liu C, Nascimento Oliver A, Jardim José R

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The purpose of this study was to verify the reproducibility between two different observers of an analysis method for diaphragmatic displacement measurements using direct visualization with videofluoroscopy.

PATIENTS AND

METHODS

29 mouth breathing children aged 5 to 12 years from both genders were analyzed. The diaphragmatic displacement evaluation was divided in three parts: videofluoroscopy with VHS recording in standing, sitting, and dorsal positions; digitalization of the images; and measurement of the distance between diaphragmatic domes during a breathing cycle using Adobe Photoshop 5.5 and Adobe Premiere PRO 6.5 software.

RESULTS

The intraclass correlation coefficients presented excellent reproducibility in all positions, with coefficients always above 0.94. Mean of the measurements of the diaphagramatic domes displacement done by the two observers were similar (P<.05), with the exception of right diaphragmatic displacement in the seated position and left diaphragmatic displacement in the standing position (P<.05).

CONCLUSION

This study demonstrated that the evaluation of diaphragmatic displacement via videofluoroscopy is a reproducible measurement when two trained investigators are compared. This fact indicates that the present technique can be disseminated and performed by other healthcare professionals.

Для цитирования: Yi Liu C, Nascimento Oliver A, Jardim José R. Reliability of an analysis method for measuring diaphragm excursion by means of direct visualization with videofluoroscopy.. Archivos de bronconeumologia. 2011. DOI: 10.1016/j.arbres.2010.12.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.