MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acssensors.5c00478

Медицинская библиотека · ACS sensors · 2025

Deciphering the Humidity Resistance and Oxygen-Content Independence of Conductometric Hydrogen Sulfide Sensors Based on Electrospun CeO2/CuO Nanotubes.

Wang Yanjie, Wang Mengqing, Jiang Xinke, She Xiaopeng, Chen Yi, Long Yin, Zhou Yong

СтатьяПеревод в очереди

Аннотация

Limited by inherent physicochemical properties and surface-adsorption-dominated gas-sensing behavior, traditional metal oxides are susceptible to ambient humidity levels and oxygen content within test environments. To overcome this issue, we proposed one highly sensitive MEMS-type H2S sensor featuring electrospun cerium oxide (CeO2)/copper oxide (CuO) nanotubes as the sensing layer. The constituent ratio-optimized sensors (CeO2/CuO-5) exhibited superior H2S-sensing performance over pure CeO2 counterparts, including lower operation temperature, more than two times stronger response (7.4 vs 3.1@4 ppm), and favorable selectivity. Density functional theory calculations and a series of characterization methods found that the increased oxygen vacancies and abundant CeO2/CuO n-p heterojunctions jointly contributed to the promotion of receptor and transducer function. In addition, a humidity-resistant and oxygen content-independent sensor performance was demonstrated. On the one hand, the self-refreshing effect of CeO2 endowed the CeO2/CuO-5 sensor with 75.6% retention of response toward 4 ppm of H2S under 70% RH with respect to the dry case, thus showcasing an excellent humidity tolerance. On the other hand, the decent oxygen storage ability of CeO2 favored a high response even under oxygen-lean environments. Furthermore, a patrol monitor apparatus loaded with the as-prepared sensor was designed, which showed efficient detection and alerting for on-site H2S leakage.

Для цитирования: Wang Yanjie, Wang Mengqing, Jiang Xinke, She Xiaopeng, Chen Yi, Long Yin, Zhou Yong. Deciphering the Humidity Resistance and Oxygen-Content Independence of Conductometric Hydrogen Sulfide Sensors Based on Electrospun CeO2/CuO Nanotubes.. ACS sensors. 2025. DOI: 10.1021/acssensors.5c00478.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.