MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.prosdent.2025.12.007

Медицинская библиотека · The Journal of prosthetic dentistry · 2026

Anomaly detection of screw loosening of different implant-abutment connection designs using resonance frequency analysis: An in vitro study.

Sammour Sara Reda, Naito Hideki, Shigemitsu Ryuji, Xie Ziqi, Kimoto Tomoyuki, Sasaki Keiichi, Yoda Nobuhiro, Ogawa Toru

СтатьяПеревод в очереди

Аннотация

STATEMENT OF PROBLEM: Screw loosening is a common mechanical complication in implant-supported restorations, yet early detection remains challenging because of the lack of noninvasive, quantitative assessment tools.

PURPOSE: This in vitro study aimed to evaluate the ability of resonance frequency analysis (RFA) combined with machine learning techniques to detect screw loosening in 3 implant-abutment connection designs: conical, internal tri-channel, and external hexagonal.

MATERIAL AND

METHODS

Three connection types were tested using 6 implants inserted into mandibular jaw models. RFA was conducted using a triaxial accelerometer under 7 loosening conditions with the frequency responses in the x, y, and z directions being recorded. Supervised learning (random forest) was used for binary (intact versus abnormal) and multiclass (7 classes) classification. Unsupervised learning was used to detect anomalies.

RESULTS

The RFA revealed unique vibrational profiles for each connection design. The random forest classifier achieved 100% accuracy in binary classification and 83% to 92% in multiclass classification. Feature importance analysis highlighted the relevance of the triaxial vibration data. The convolutional autoencoder consistently identified screw loosening as early as 5 degrees.

CONCLUSIONS

RFA combined with machine learning reliably detected screw loosening across various types of implant-abutment connections. This method offers a noninvasive, quantitative tool for the early detection of mechanical complications in implant dentistry.

Для цитирования: Sammour Sara Reda, Naito Hideki, Shigemitsu Ryuji, Xie Ziqi, Kimoto Tomoyuki, Sasaki Keiichi, Yoda Nobuhiro, Ogawa Toru. Anomaly detection of screw loosening of different implant-abutment connection designs using resonance frequency analysis: An in vitro study.. The Journal of prosthetic dentistry. 2026. DOI: 10.1016/j.prosdent.2025.12.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.