MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/hed.21568

Медицинская библиотека · Head & neck · 2010

Extraction of a headscarf pin from the vertebral artery without embolization.

Ilan Ophir, Weinberger Jeffrey M, Gomori J Moshe, Gross Menachem

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Foreign bodies traversing the aerodigestive tract lining into the surrounding soft tissues is a well-known entity. A 14-year-old girl was referred to our hospital after swallowing a pin that was not visualized by laryngoscopy, despite a neck film that localized it to the level of the larynx.

METHODS

A CT scan demonstrated a bent pin piercing the left vertebral artery "through and through," and this was confirmed by angiography. The pin was extracted via an external approach to the neck without preoperative intravascular manipulation.

RESULTS

Angiography immediately after the surgery demonstrated a stable thrombotic sleeve in the vertebral artery without further clot propagation or bleeding from the vessel wall. This is the first report of a "through and through" thrombotic sleeve in an artery.

CONCLUSIONS

Simple surgical removal of a sharp foreign body from the vertebral artery without intravascular management may be a reasonable option.

Для цитирования: Ilan Ophir, Weinberger Jeffrey M, Gomori J Moshe, Gross Menachem. Extraction of a headscarf pin from the vertebral artery without embolization.. Head & neck. 2010. DOI: 10.1002/hed.21568.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.