m+Medelevator.RU
← Поиск публикаций
European radiology · 2018

Magnetic resonance hysterosalpingography in diagnostic work-up of female infertility - comparison with conventional hysterosalpingography: a randomised study.

СтатьяРандомизированное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Volondat Manuelle, Fontas Eric, Delotte Jerome, Fatfouta Imene, Chevallier Patrick, Chassang Madleen

Аннотация

OBJECTIVE: To compare diagnostic accuracy of MR-hysterosalpingography (MR-HSG) and conventional hysterosalpingography (X-HSG) in the evaluation of female infertility.

METHODS: Forty women received prospectively both X-HSG, the gold standard technique, and MR-HSG on the same day but the order in which they were conducted was randomised. A 1.5 Tesla MRI was performed with classical sequences for pelvic analysis and an additional 3D T1-weighted sequence with intra-uterine injection of gadolinium. Two radiologists independently interpreted X-HSG and MR-HSG according to randomisation, blinded to the other results. They both then performed a second interpretation of MR-HSG blinded to the first reading with a minimum time delay of 1 week. Diagnostic performance of MR-HSG for analysis of tubal and intracavity abnormalities was evaluated by calculating sensitivity (Se), specificity (Sp), positive predictive value (PPV) and negative predictive value (NPV).

RESULTS: Twenty-six patients were included. Diagnostic performance of MR-HSG was: Se: 91.7% (95% CI 61.5-99.8); Sp: 92.9% (95% CI 66.1-99.8) ; PPV: 91.7% (95% CI 61.5-99.8); NPV: 92.9% (95% CI 66.1-99.8). Pain analysis showed a significant statistical difference between the two procedures: average VAS for X-HSG was 4.43 (95% CI 3.50-5.36) versus 3.46 (95% CI 2.62-4.31) for MR-HSG, p=0,01. Intra- and inter-rater agreements for detection of tubal or intracavity abnormalities were 0.92 (95% CI 0.78-1.00) and 0.76 (95% CI 0.52-1.00).

CONCLUSION: MR-HSG is a well-tolerated technique demonstrating high accuracy in investigating tubal patency and intra-uterine abnormalities for diagnostic work-up of female infertility.

KEY POINTS: • MR-hysterosalpingography is an innovative technique. • Hysterosalpingography can be used to investigate tubal patency and intracavity abnormalities. • Hysterosalpingography is a potential 'one-stop-shop' imaging technique for a single comprehensive examination of female infertility.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты