MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0896860820945813

Медицинская библиотека · Peritoneal dialysis international : journal of the International Society for Peritoneal Dialysis · 2020

Tracking hydration status changes by bioimpedance spectroscopy in children on peritoneal dialysis.

Karava Vasiliki, Stabouli Stella, Dotis John, Liakopoulos Vassilios, Papachristou Fotios, Printza Nikoleta

СтатьяПеревод в очереди

Аннотация

BACKGROUND

This 6-month prospective longitudinal study investigates the association between hydration status changes using bioimpedance spectroscopy (BIS) and systolic blood pressure (SBP), pulse pressure (PP), and serum albumin (sAlb) changes in children on peritoneal dialysis (PD).

METHODS

Thirteen patients (median age: 12.58 years) were enrolled. Normal hydration, moderate hydration, severe overhydration, and dehydration were defined as -7% ≤ relative overhydration (Re-OH) < +7%, +7% ≤ Re-OH < +15%, Re-OH ≥ +15%, and Re-OH < -7%, respectively. Automated office blood pressure z-score, sAlb, and weight z-score were recorded.

RESULTS

Fifty-two Re-OH measurements were recorded: three in five, four in five, five in two, and seven in one patient, respectively. SBP was higher and sAlb lower in cases with severe overhydration (9 readings) (p < 0.001, p < 0.001), but distribution of these parameters did not differ between normal hydration/dehydration (28 readings) and moderate overhydration (15 readings) cases. In patients with hydration status change, SBP and PP were higher while sAlb lower in cases with higher hydration status level (p = 0.026, p = 0.05, and p = 0.109, respectively). In all patients, visit-to-visit SBP, PP, and sAlb changes were correlated to Re-OH changes (rs = 0.693, p < 0.001; rs = 0.643, p < 0.001; rs = -0.444, p = 0.008, respectively) but not to weight changes (rs = 0.052, p = 0.754; rs = 0.034, p = 0.838; rs = -0.156, p = 0.378, respectively). Visit-to-visit Re-OH changes, which were >+4% or <-4%, were linearly correlated to SBP (r = 0.858, p < 0.001), PP (r = 0.757, p < 0.001), and sAlb (r = -0.699, p = 0.002) changes.

CONCLUSION

In children on PD, longitudinal Re-OH changes are superior to weight changes in assessing volume-dependent variations of SBP, PP, and sAlb. Routine BIS application, rather than single BIS measurements, seems useful in the intra-patient monitoring of hydration status.

Для цитирования: Karava Vasiliki, Stabouli Stella, Dotis John, Liakopoulos Vassilios, Papachristou Fotios, Printza Nikoleta. Tracking hydration status changes by bioimpedance spectroscopy in children on peritoneal dialysis.. Peritoneal dialysis international : journal of the International Society for Peritoneal Dialysis. 2020. DOI: 10.1177/0896860820945813.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.