MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jemermed.2017.12.044

Медицинская библиотека · The Journal of emergency medicine · 2018

Resuscitative Endovascular Balloon Occlusion of the Aorta Using a Low-Profile Device is Easy and Safe for Emergency Physicians in Cases of Life-Threatening Hemorrhage.

Shoji Takahiro, Tarui Takehiko, Igarashi Takashi, Mochida Yuki, Morinaga Hiroyuki, Miyakuni Yasuhiko, Inoue Yoshitaka, Kaita Yasuhiko, Miyauchi Hiroshi, Yamaguchi Yoshihiro

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Bleeding from hemorrhagic shock can be immediately controlled by blocking the proximal part of the hemorrhagic point using either resuscitative thoracotomy for aortic cross-clamping or insertion of a large-caliber (10-14Fr) resuscitative endovascular balloon occlusion of the aorta (REBOA) device via the femoral artery. However, such methods are very invasive and have various complications. With recent progress in endovascular treatment, a low-profile REBOA device (7Fr) has been developed.

OBJECTIVE

The objective of this study was to report our experience of this low-profile REBOA device and to evaluate the usefulness of emergency physician-operated REBOA in life-threatening hemorrhagic shock.

METHODS

Ten patients with refractory hemorrhagic shock underwent REBOA using this device via the femoral artery. All REBOA procedures were performed by emergency physicians. The success rate of the insertion, vital signs, and REBOA-related complications were evaluated.

RESULTS

Median age was 54 years (interquartile range 33-78 years). The causes of hemorrhagic shock were trauma (n = 4; 1 blunt and 3 penetrating), ruptured abdominal aortic aneurysm (n = 3), and obstetric hemorrhage (n = 3). Two patients had cardiopulmonary arrest upon arrival. REBOA procedure was successful in all patients, and all became hemodynamically stable to undergo definitive interventions after REBOA. There were no REBOA-related complications. The mortality rate within 24 h and 30 days was 40%.

CONCLUSIONS

This REBOA device was useful for emergency physicians in life-threatening hemorrhagic shock because of its ease in handling and low invasiveness.

Для цитирования: Shoji Takahiro, Tarui Takehiko, Igarashi Takashi, Mochida Yuki, Morinaga Hiroyuki, Miyakuni Yasuhiko, Inoue Yoshitaka, Kaita Yasuhiko, Miyauchi Hiroshi, Yamaguchi Yoshihiro. Resuscitative Endovascular Balloon Occlusion of the Aorta Using a Low-Profile Device is Easy and Safe for Emergency Physicians in Cases of Life-Threatening Hemorrhage.. The Journal of emergency medicine. 2018. DOI: 10.1016/j.jemermed.2017.12.044.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.