MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jaapos.2012.11.008

Медицинская библиотека · Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus · 2013

Plusoptix photoscreening may replace cycloplegic examination in select pediatric ophthalmology patients.

Silbert David I, Matta Noelle S, Andersen Kristen

СтатьяПеревод в очереди

Аннотация

PURPOSE: To determine whether children presenting to a pediatric ophthalmologist and found to have a normal Plusoptix photoscreener (PlusoptiX GmbH, Nuremberg, Germany) result, normal visual acuity (children age 3+), and normal alignment/motility receive additional benefit from a dilated fundus examination.

METHODS

The medical records of all children seen at one pediatric ophthalmology practice between 2007 and 2010 who were coded as having had a photoscreening were retrospectively reviewed. Of the total number of records identified, one-half were selected randomly for review. Patients who underwent plusoptiX screening on the first visit were included. Patients with abnormal alignment and/or abnormal vision as well as those referred for examination as determined by a medical or ophthalmic condition that required a dilated fundus examination were excluded.

RESULTS

Of 1,377 patients identified, 697 were selected randomly for record review. Of these, 451 had had an initial plusoptiX screening. A total of 222 had a normal result. Of the 190 patients analyzed, cycloplegic examination provided additional diagnostic information for only 4 children: 1 with nonvisually significant congenital cataract, 1 with refractive amblyopia from moderate astigmatism, 1 with moderate hyperopia who later was found to have accommodative esotropia, and 1 with increased cupping but normal IOP.

CONCLUSIONS

A normal plusoptiX result, combined with normal alignment/motility evaluation and visual acuity was found to have a 98% negative predictive value for ophthalmic pathology, including significant refractive error. The plusoptiX and an abbreviated eye examination may obviate the need for dilation in select children.

Для цитирования: Silbert David I, Matta Noelle S, Andersen Kristen. Plusoptix photoscreening may replace cycloplegic examination in select pediatric ophthalmology patients.. Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus. 2013. DOI: 10.1016/j.jaapos.2012.11.008.