MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.msard.2024.105753

Медицинская библиотека · Multiple sclerosis and related disorders · 2024

Association of retinal microvascular curve tortuosity and multiple sclerosis: A cross-section analysis from the UK Biobank.

Jiang Yuzhe, Chen Qi, Shi Danli, Miao Suyu, Liu Yifeng, Wang Jinyang, Liu Lin, Chen Yufan, Wang Ruobing

СтатьяПеревод в очереди

Аннотация

BACKGROUND

There is growing evidence supporting that vascular abnormalities contribute to multiple sclerosis (MS), and retinal microvasculature functions as a visible window to observe vessels. We hypothesized that retinal vascular curve tortuosity is associated with MS, which this study aims to address.

METHODS

Participants from the UK Biobank with complete clinical records and gradable fundus photos were included in the study. Arteriolar and venular curve tortuosity and vessel area density are quantified automatically using a deep learning system. Individuals with MS were matched to healthy controls using propensity score matching (PSM). Conditional logistic regression was used to investigate the association between retinal vascular characteristics and MS. We also used a receiver operating characteristic (ROC) curve to assess the diagnostic performance of MS.

RESULTS

Venular curve tortuosity (VCT) was found to be significantly associated with MS. And patients with multiple sclerosis were probable to have lower VCT than the non-MS group (OR = 0.22 [95 % CI, 0.05 to 0.92], P < 0.05).

CONCLUSIONS

Our study reveals a significant association between vessel curve tortuosity and MS. The lower curve tortuosity of the retinal venular network may indicate a higher risk of incident multiple sclerosis.

Для цитирования: Jiang Yuzhe, Chen Qi, Shi Danli, Miao Suyu, Liu Yifeng, Wang Jinyang, Liu Lin, Chen Yufan, Wang Ruobing. Association of retinal microvascular curve tortuosity and multiple sclerosis: A cross-section analysis from the UK Biobank.. Multiple sclerosis and related disorders. 2024. DOI: 10.1016/j.msard.2024.105753.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.