MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/heart.90.1.70

Медицинская библиотека · Heart (British Cardiac Society) · 2004

Long term results of percutaneous balloon valvoplasty of congenital aortic stenosis: independent predictors of outcome.

Reich O, Tax P, Marek J, Rázek V, Gilík J, Tomek V, Chaloupecký V, Bartáková H, Skovránek J

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To evaluate long term results and independent predictors of outcome of aortic valvoplasty.

DESIGN

Retrospective follow up study. Independent predictors of outcome identified by multiple logistic regression.

SETTING

Tertiary referral centre.

PATIENTS: 269 consecutive patients treated at the median age of 8 months (0-23 years): 80 (30%) under 4 weeks, 59 (22%) between 4 weeks and 1 year, and 130 (48%) over 1 year. The follow up period was up to 14.8 years (median 5.3, in survivors 6.4 years).

INTERVENTIONS: Percutaneous balloon valvoplasty with mean (SD) balloon to annulus ratio 0.97 (0.08).

MAIN OUTCOME MEASURES: Restenosis > or = 70 mm Hg, grade 3 aortic insufficiency, cusps disruption, surgery, death, and valvoplasty failure (significant restenosis or insufficiency or surgery or death).

RESULTS

The mortality rate was 10.4% (n = 28), the restenosis rate was 16.7% (n = 45), significant insufficiency developed in 22.3% (n = 60), surgery was needed in 20.1% (n = 54), and "valvoplasty failure" occurred in 41.6% (n = 112) patients. Mean (SEM) survival probability 14.4 years after the procedure was 0.89 (0.02) and mean (SEM) probability of surgery-free survival was 0.50 (0.08). The independent predictors were as follows. For restenosis: small aortic annulus; for cusp disruption: large aortic annulus; for insufficiency: bicuspid aortic valve; for need for surgery: bicuspid aortic valve; for death: small aortic annulus, low left ventricular shortening fraction, and low sequential number of the valvoplasty; and for valvoplasty failure: small aortic annulus, bicuspid aortic valve, and high grade of mitral insufficiency.

CONCLUSION

Independent predictors of unfavourable outcome are small aortic annulus, bicuspid aortic valve, poor function of left ventricle or mitral valve, and limited operator experience.

Для цитирования: Reich O, Tax P, Marek J, Rázek V, Gilík J, Tomek V, Chaloupecký V, Bartáková H, Skovránek J. Long term results of percutaneous balloon valvoplasty of congenital aortic stenosis: independent predictors of outcome.. Heart (British Cardiac Society). 2004. DOI: 10.1136/heart.90.1.70.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.