Evaluation of myocardial perfusion and function by gated single-photon emission computed tomography technetium-99m methoxyisobutylisonitrile in children and adolescents with severe congenital heart disease.

Sobic-Saranovic Dragana P, Pavlovic Smiljana V, Jovanovic Ida V, Stefanovic Igor D, Artiko Vera M, Djukic Milan M, Obradovic Vladimir B

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

The value of gated single-photon emission computed tomography technetium-99m methoxyisobutylisonitrile (gated SPECT (99m)Tc-MIBI) in children is not yet established probably because gated SPECT (99m)Tc-MIBI has rarely been used in pediatric clinical and research studies. The purpose of this study was to evaluate perfusion abnormalities and left ventricular (LV) function by gated SPECT (99m)Tc-MIBI in children and adolescents with severe congenital heart disease (CHD).

METHODS

Seventeen children and adolescents with severe CHD (11 boys and six girls, mean age 11+/-4 years) underwent 2-day rest-stress (11 boys) or 1-day rest (six girls) gated SPECT (99m)Tc-MIBI. Myocardial perfusion was evaluated by a 17-segment model with a 5-point score to derive the summed stress score, the summed rest score (SRS), and the summed difference score based on the 4D-MSPECT software results. The extent of myocardial perfusion abnormalities was also expressed as a percentage of the LV size. The 4D-MSPECT software was used to calculate LV end-diastolic volume, end-systolic volume (ESV), and ejection fraction (EF).

RESULTS

Reversible myocardial perfusion defect was found in 7 of 11 children (64%) who underwent rest-stress gated SPECT (99m)Tc-MIBI. The LV segments involved were anterior, anteroseptal, anterolateral, apical and inferior. These seven children showed significantly larger perfusion abnormalities on stress compared with rest study (18+/-5 vs. 7+/-4%, P<0.01) and higher summed stress score compared to SRS (11+/-4 vs. 4+/-2, P<0.01). Children and adolescents with myocardial ischemia had significantly lower poststress EF than rest EF (53+/-12 vs. 59+/-11%, P<0.05) and significantly higher poststress ESV than rest ESV (81+/-24 vs. 61+/-25 ml, P<0.05). In six children evaluated only at rest, perfusion defects involved anterior, anteroseptal and apical, or inferolateral segments, accounting for 31+/-12% of LV and with SRS of 12+/-5. Their global LV parameters were: end-diastolic volume 118+/-23 ml, ESV 56+/-16 ml, EF 51+/-10%.

CONCLUSION

Poststress and rest-gated SPECT (99m)Tc-MIBI results indicate that children and adolescents with severe CHD show a range of abnormalities in myocardial perfusion and LV function, which is useful for determining functional importance of morphological malformations. Thus, gated SPECT (99m)Tc-MIBI provides complementary information that may guide clinical decision making in children and adolescents with severe CHD.

Для цитирования: Sobic-Saranovic Dragana P, Pavlovic Smiljana V, Jovanovic Ida V, Stefanovic Igor D, Artiko Vera M, Djukic Milan M, Obradovic Vladimir B. Evaluation of myocardial perfusion and function by gated single-photon emission computed tomography technetium-99m methoxyisobutylisonitrile in children and adolescents with severe congenital heart disease.. Nuclear medicine communications. 2010. DOI: 10.1097/mnm.0b013e3283295622.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.