MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2009.12.047

Медицинская библиотека · The Annals of thoracic surgery · 2010

Partial replacement of tricuspid valve using cryopreserved homograft.

Shrestha Bishwo M S, Fukushima Satsuki, Vrtik Marian, Chong Ian H, Sparks Lisa, Jalali Homayoun, Pohlner Peter G

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The optimal choice of prosthesis for tricuspid valve (TV) replacement is yet to be determined. Partial replacement of the TV using a homograft atrioventricular valve might offer resistance to infection, good durability, and excellent functionality, in addition to avoiding prosthesis-related morbidity.

METHODS

We present 14 patients who underwent replacement of the TV using a homograft between 1997 and 2008. The mean age at operation was 32 years, including 5 patients younger than the age of 10. All patients preoperatively showed severe TV regurgitation as a result of active infective endocarditis in 5 patients, Ebstein anomaly in 4 patients, other cardiac anomalies in 4 patients, and rheumatic valvular disease in 1 patient. The TV homograft was used in 13 patients, and mitral homograft was used in 1 patient. Eleven patients had replacement of one leaflet only, whereas 3 patients required replacement of two leaflets. Concomitant cardiac procedures were performed in 7 patients.

RESULTS

No mortalities occurred during the average postoperative follow-up of 61 months (range, 12 to 126 months). Reoperation for TV regurgitation after TV repair with homograft was performed in 3 patients. The remaining 11 patients had minimal symptoms without reintervention for TV regurgitation.

CONCLUSIONS

Partial replacement of the TV using a homograft provided good hospital and mid-term outcomes. This strategy might be useful in active infective endocarditis and congenital TV disease.

Для цитирования: Shrestha Bishwo M S, Fukushima Satsuki, Vrtik Marian, Chong Ian H, Sparks Lisa, Jalali Homayoun, Pohlner Peter G. Partial replacement of tricuspid valve using cryopreserved homograft.. The Annals of thoracic surgery. 2010. DOI: 10.1016/j.athoracsur.2009.12.047.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.