MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.12690

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2015

Pediatric Dilated Cardiomyopathy Patients Do Not Meet Traditional Cardiac Resynchronization Criteria.

Schiller Ofer, Dham Niti, Greene E Anne, Heath Deneen M, Alexander Mark E, Berul Charles I

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

Cardiac resynchronization therapy (CRT) is an effective device-based intervention for adults with heart failure (HF) with specific indications, based on large, multicenter randomized clinical trials. The criteria for CRT in adult HF include significant symptoms, ventricular systolic dysfunction, prolonged QRS duration, and left bundle branch block (LBBB) pattern on electrocardiogram (ECG). Despite having less data, CRT is also being widely utilized in children with HF. The shortage of evidence-based CRT criteria in pediatrics prompted us to review a cohort of children with dilated cardiomyopathy and evaluate their potential eligibility for CRT using the traditional adult criteria.

METHODS

Single-center data of all pediatric patients with dilated cardiomyopathy were extracted from the heart failure registry and retrospectively reviewed. Patients who had at least 2 separate visits that included HF scoring, electrocardiogram, and echocardiogram were included. Patients who were ventricular paced were excluded.

RESULTS

Data for 52 patients meeting inclusion criteria were analyzed. The mean ejection fraction was 25% on the first clinical evaluation and 27% on the second visit. No patient and 2 patients met the adult criteria for prolonged QRS on the first and second encounters, respectively. No patients had an LBBB pattern on ECG.

CONCLUSIONS

None of the pediatric HF patients in our study met the published Class I criteria for CRT device therapy in adults. These findings suggest that extrapolation of adult HF data to pediatrics is not sufficient for CRT criteria. Specific guidelines for device implantation in children must be based on scientific investigation including pediatric clinical trials.

Для цитирования: Schiller Ofer, Dham Niti, Greene E Anne, Heath Deneen M, Alexander Mark E, Berul Charles I. Pediatric Dilated Cardiomyopathy Patients Do Not Meet Traditional Cardiac Resynchronization Criteria.. Journal of cardiovascular electrophysiology. 2015. DOI: 10.1111/jce.12690.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.