OBJECTIVES

Our aim is to describe our surgical approach in dealing with patients having atrioventricular septal defect with common atrioventricular junction and ventricular shunting associated with tetralogy of Fallot over the last 8 years, and to present our results in mid-to-long term follow-up.

METHODS

Between November 1995 and January 2004, we performed surgical correction in 8 consecutive children with atrioventricular septal defect, common atrioventricular junction, interventricular shunting, and associated tetralogy of Fallot. The age at surgical correction varied from 8 months to 20 years, with a mean of 45 months, and standard deviation of 74 months. A palliative systemic-to-pulmonary shunt had previously been performed in 3 patients. Follow-up ranged from 57 to 135 months, with a mean of 93.5 months, and standard deviation of 32 months. We used a two-patch technique to repair of the atrioventricular septal defect, and a pericardial transjunctional patch for relief of the obstruction in the right ventricular outflow tract.

RESULTS

There were no deaths, nor reoperations either in the postoperative period or during follow-up. All patients are asymptomatic, or in the second class created by the New York Heart Association. The mean period of cardiopulmonary by-pass was 136 minutes, and the mean stay in hospital was 11.8 days. At the last examination, pulmonary valvar insufficiency was considered severe in 2 patients, and moderate in another 2. No patient developed more than a trace of regurgitation across the reconstituted left atrioventricular valve.

CONCLUSIONS

The two-patch technique, associated with ventriculotomy and a transjunctional pulmonary patch is safe and efficient when correcting atrioventricular septal defect associated with tetralogy of Fallot, resulting in good mid-to-long term clinical outcomes.

Для цитирования: Canale Leonardo S, Monteiro Andrey J O, Rangel Isabela, Pinto Divino F, Soares Paulo, Barbosa Rosa C, Meier Milton A, Marcial Miguel L B. Mid-to-long term follow-up after surgical repair of atrioventricular septal defect with common atrioventricular junction and ventricular shunting associated with tetralogy of Fallot.. Cardiology in the young. 2008. DOI: 10.1017/s1047951107001874.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.