Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2003
Endovascular repair of external iliac artery occlusion after hip prosthesis migration.
Клинический случайСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kwolek Christopher J, Matthews Marc R, Hartford James M, Minion David J, Schwarcz Thomas H, Quick Rhonda, Endean Eric
Аннотация
PURPOSE: To report emergent endovascular intervention to restore lower extremity arterial patency after migration of a hip prosthesis caused thrombosis of the external iliac artery (EIA).
CASE REPORT: Nine months following left hip revision arthroplasty, a 66-year-old woman presented to the Emergency Department with the complaints of an acutely painful left lower extremity for over 6 hours. Imaging showed the metallic acetabular portion of the hip prosthesis in the iliac fossa, with severe external compression of the EIA. After thrombolysis to remove clot from the EIA, an 8x60-mm self-expanding Smart stent was deployed in the left EIA from a contralateral access. The procedure was successful, and the patient was discharged. An infected wound from a compartment fasciotomy delayed revision of the hip prosthesis. Nine weeks after stenting, the patient returned with a cold, pulseless left limb; a femorofemoral bypass was constructed to restore perfusion.
CONCLUSIONS: While stent placement restored flow for 9 weeks after the initial ischemic event, the recurrent thrombosis could have been prevented by earlier revision of the migrated prosthesis.
CASE REPORT: Nine months following left hip revision arthroplasty, a 66-year-old woman presented to the Emergency Department with the complaints of an acutely painful left lower extremity for over 6 hours. Imaging showed the metallic acetabular portion of the hip prosthesis in the iliac fossa, with severe external compression of the EIA. After thrombolysis to remove clot from the EIA, an 8x60-mm self-expanding Smart stent was deployed in the left EIA from a contralateral access. The procedure was successful, and the patient was discharged. An infected wound from a compartment fasciotomy delayed revision of the hip prosthesis. Nine weeks after stenting, the patient returned with a cold, pulseless left limb; a femorofemoral bypass was constructed to restore perfusion.
CONCLUSIONS: While stent placement restored flow for 9 weeks after the initial ischemic event, the recurrent thrombosis could have been prevented by earlier revision of the migrated prosthesis.