Quality-controlled dose-reduction of pelvic X-ray examinations in infants with hip dysplasia.

Kloth Jost Karsten, Neumann Regina, von Stillfried Eva, Stiller Wolfram, Burkholder Iris, Kauczor Hans-Ulrich, Ewerbeck Volker, Weber Marc-André

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Digital plain radiography (DR) examinations of the pelvis are frequently performed in infants with hip dysplasia.

OBJECTIVE

The purpose was to reduce the radiation dose and to determine objective quality control criteria to ensure accurate assessment. This seems feasible because of higher quantum efficiency of DR and easy assessable anatomical structures for most orthopaedic measurements.

MATERIALS AND

METHODS

Institutional review board approval was obtained. In this prospective randomized study, 264 patients underwent X-ray examination of the pelvis with standard and reduced dose. The evaluation of the plain-radiographs was conducted using the following criteria: acetabular and center edge angle, closing of the epiphyseal plates and maturation of the femoral head. Two radiologists evaluated these criteria using a score ranging from 1 (definitely assessable) to 4 (not assessable). If a single criterion had been evaluated with a score of 3 or more points or more than 2 criteria with 2 points, the radiograph was scored as "not assessable". The statistical analysis was conducted as non-inferiority-trial.

RESULTS

Five (1.9%) examined X-rays were scored as not assessable. There was no statistical inferiority between the examinations with standard (4.57 μSv) or reduced dose (3.06 μSv). Also, the individual evaluation of the defined criteria was dose-independent.

CONCLUSION

The adequate evaluation of hip dysplasia in children and young adults on pelvic radiographs is possible with reduced radiation dose, by simple using an exposure class of 800 instead of 400.

Для цитирования: Kloth Jost Karsten, Neumann Regina, von Stillfried Eva, Stiller Wolfram, Burkholder Iris, Kauczor Hans-Ulrich, Ewerbeck Volker, Weber Marc-André. Quality-controlled dose-reduction of pelvic X-ray examinations in infants with hip dysplasia.. European journal of radiology. 2015. DOI: 10.1016/j.ejrad.2015.11.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.