Pulmonary embolism in patients with transvenous cardiac implantable electronic device leads.

Noheria Amit, Ponamgi Shiva P, Desimone Christopher V, Vaidya Vaibhav R, Aakre Christopher A, Ebrille Elisa, Hu Tiffany, Hodge David O, Slusser Joshua P, Ammash Naser M, Bruce Charles J, Rabinstein Alejandro A, Friedman Paul A, Asirvatham Samuel J

СтатьяНаблюдательное исследованиеПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

Cardiac implantable electronic devices (CIEDs) are commonly associated with transvenous lead-related thrombi that can cause pulmonary embolism (PE).

METHODS AND

RESULTS

We retrospectively evaluated all patients with transvenous CIED leads implanted at Mayo Clinic Rochester between 1 January 2000, and 25 October 2010. Pulmonary embolism outcomes during follow-up were screened using diagnosis codes and confirmed with imaging study reports. Of 5646 CIED patients (age 67.3 ± 16.3 years, 64% men, mean follow-up 4.69 years) 88 developed PE (1.6%), incidence 3.32 [95% confidence interval (CI) 2.68-4.07] per 1000 person-years [men: 3.04 (95% CI 2.29-3.96) per 1000 person-years; women: 3.81 (95% CI 2.72-5.20) per 1000 person-years]. Other than transvenous CIED lead(s), 84% had another established risk factor for PE such as deep vein thrombosis (28%), recent surgery (27%), malignancy (25%), or prior history of venous thromboembolism (15%). At the time of PE, 22% had been hospitalized for ≥ 48 h, and 59% had been hospitalized in the preceding 30 days. Pulmonary embolism occurred in 22% despite being on systemic anticoagulation therapy. Out of 88 patients with PE, 45 subsequently died, mortality rate 93 (95% CI 67-123) per 1000 person-years (hazard ratio 2.0, 95% CI 1.5-2.7, P < 0.0001).

CONCLUSIONS

Though lead-related thrombus is commonly seen in patients with transvenous CIED leads, clinical PE occurs with a low incidence. It is possible that embolism of lead thrombus is uncommon or emboli are too small to cause consequential pulmonary infarction.

Для цитирования: Noheria Amit, Ponamgi Shiva P, Desimone Christopher V, Vaidya Vaibhav R, Aakre Christopher A, Ebrille Elisa, Hu Tiffany, Hodge David O, Slusser Joshua P, Ammash Naser M, Bruce Charles J, Rabinstein Alejandro A, Friedman Paul A, Asirvatham Samuel J. Pulmonary embolism in patients with transvenous cardiac implantable electronic device leads.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2015. DOI: 10.1093/europace/euv038.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.