MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/jaha.119.013278

Медицинская библиотека · Journal of the American Heart Association · 2019

Metabolic Dysfunction in Continuous-Flow Left Ventricular Assist Devices Patients and Outcomes.

Nguyen Ann B, Imamura Teruhiko, Besser Stephanie, Rodgers Daniel, Chung Ben, Raikhelkar Jayant, Kalantari Sara, Smith Bryan, Sarswat Nitasha, LaBuhn Colleen, Jeevanandam Valluvan, Kim Gene, Sayer Gabriel, Uriel Nir

СтатьяПеревод в очереди

Аннотация

Background Metabolic impairment is common in heart failure patients. Continuous-flow left ventricular assist devices (CF-LVADs) improve hemodynamics and outcomes in patients with advanced heart failure; however, the effect of CF-LVADs on metabolic status is unknown. This study aims to evaluate the changes in metabolic status following CF-LVAD implantation and measure the correlation of metabolic status with outcomes. Methods and Results Prospective data on CF-LVAD patients were obtained. Metabolic evaluation, including hemoglobin A1C, free and total testosterone, thyroid-stimulating hormone (TSH), and free T4, was obtained before and at multiple time points following implantation. Patients with nonelevated thyroid-stimulating hormone and normal hemoglobin A1C and testosterone levels were defined as having normal metabolic status. Baseline characteristics, hemodynamics, and outcomes were collected. One hundred six patients were studied, of which 56 had paired data at baseline and 1- to 3-month follow-up. Before implantation, 75% of patients had insulin resistance, 86% of men and 39% of women had low free testosterone, and 44% of patients had abnormal thyroid function. There was a significant improvement in hemoglobin A1C, free testosterone, and thyroid-stimulating hormone following implantation (P<0.001 for all). Patients with normal hemoglobin A1C (<5.7%) following implantation had higher 1-year survival free of heart failure readmissions (78% versus 23%; P<0.001). Patients with normal metabolic status following implantation also had higher 1-year survival free of heart failure readmissions (92% versus 54%; P=0.04). Conclusions Metabolic dysfunction is highly prevalent in advanced heart failure patients and improves after CF-LVAD implantation. Normal metabolic status is associated with a significantly higher rate of 1-year survival free of heart failure readmissions.

Для цитирования: Nguyen Ann B, Imamura Teruhiko, Besser Stephanie, Rodgers Daniel, Chung Ben, Raikhelkar Jayant, Kalantari Sara, Smith Bryan, Sarswat Nitasha, LaBuhn Colleen, Jeevanandam Valluvan, Kim Gene, Sayer Gabriel, Uriel Nir. Metabolic Dysfunction in Continuous-Flow Left Ventricular Assist Devices Patients and Outcomes.. Journal of the American Heart Association. 2019. DOI: 10.1161/jaha.119.013278.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.