MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0296344

Медицинская библиотека · PloS one · 2024

Clinical evaluation of a fully electronic microfluidic white blood cell analyzer.

Sui Jianye, Lin Zhongtian, Azizpour Shahriar, Chen Fei, Gaur Sunanda, Keene Kelly, Soleimani Farzad, Bhowmick Tanaya, Rafique Zubaid, Javanmard Mehdi

СтатьяПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

The White Blood Cell (WBC) count is one of the key parameters signaling the health of the immune system. Abnormal WBC counts often signal a systemic insult to the body such as an underlying infection or an adverse side effect to medication. Typically, the blood collected is sent to a central lab for testing, and results come back within hours, which is often inconvenient and may delay time-sensitive diagnosis or treatment. Here, we present the CytoTracker, a fully electronic, microfluidic based instant WBC analyzer with the potential to be used at point-of-care. The CytoTracker is a lightweight, portable, affordable platform capable of quantifying WBCs within minutes using only 50 μl of blood (approximately one drop of blood). In this study, we clinically evaluated the accuracy and performance of CytoTracker in measuring WBC and granulocyte counts. A total of 210 adult patients were recruited in the study. We validated the CytoTracker against a standard benchtop analyzer (Horiba Point of Care Hematology Analyzer, ABX Micros 60). Linear dynamic ranges of 2.5 k/μl- 35 k/μl and 0.6 k/μl- 26 k/μl were achieved for total WBC count and granulocyte count with correlation coefficients of 0.97 and 0.98. In addition, we verified CytoTracker's capability of identifying abnormal blood counts with above 90% sensitivity and specificity. The promising results of this clinical validation study demonstrate the potential for the use of the CytoTracker as a reliable and accurate point-of-care WBC analyzer.

Для цитирования: Sui Jianye, Lin Zhongtian, Azizpour Shahriar, Chen Fei, Gaur Sunanda, Keene Kelly, Soleimani Farzad, Bhowmick Tanaya, Rafique Zubaid, Javanmard Mehdi. Clinical evaluation of a fully electronic microfluidic white blood cell analyzer.. PloS one. 2024. DOI: 10.1371/journal.pone.0296344.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.