Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2023
Use of Sound Touch Elastography and Sound Touch Quantification for the Noninvasive Evaluation of Portal Hypertension in a Rat Model.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Dong Bingtian, Lyu Guorong, Wang Huaming, Chen Yongjian, Wei Kaipeng
Аннотация
OBJECTIVES: In this study, we used the recently developed ultrasound elastography techniques sound touch elastography (STE) and sound touch quantification (STQ) to quantify portal hypertension (PHT) severity in a rat model of carbon tetrachloride (CCl4 )-induced cirrhotic PHT.
METHODS: In total, 60 rats were used. Various degrees of PHT were established. Liver and spleen stiffness were measured by STE (L-STE and S-STE, respectively) and STQ (L-STQ and S-STQ, respectively). We measured portal pressure (PP) after ultrasonographic examination. The performance of the STE and STQ parameters in the identification of PHT was evaluated using receiver operating characteristic (ROC) analyses.
RESULTS: Liver and spleen stiffness measurements obtained with STE and STQ correlated positively with the PP (r = 0.566-0.882, all P < .001). The areas under ROC curves for L-STE, S-STE, L-STQ, and S-STQ values were 0.931 (95% confidence interval [CI], 0.847-1.000), 0.982 (95% CI, 0.956-1.000), 0.796 (95% CI, 0.680-0.912), and 0.925 (95% CI, 0.858-0.993), respectively, for PP ≥5 mmHg; 0.937 (95% CI, 0.865-1.000), 0.938 (95% CI, 0.864-1.000), 0.967 (95% CI, 0.923-1.000), and 0.960 (95% CI, 0.897-1.000), respectively, for PP ≥10 mmHg; and 0.954 (95% CI, 0.897-1.000), 0.790 (95% CI, 0.652-0.928), 0.808 (95% CI, 0.680-0.935), and 0.740 (95% CI, 0.595-0.885), respectively, for PP ≥12 mmHg.
CONCLUSIONS: STE and STQ are reliable noninvasive tools for the assessment of PHT severity, especially for PP ≥10 mmHg, in a rat model of CCl4 -induced cirrhotic PHT.
METHODS: In total, 60 rats were used. Various degrees of PHT were established. Liver and spleen stiffness were measured by STE (L-STE and S-STE, respectively) and STQ (L-STQ and S-STQ, respectively). We measured portal pressure (PP) after ultrasonographic examination. The performance of the STE and STQ parameters in the identification of PHT was evaluated using receiver operating characteristic (ROC) analyses.
RESULTS: Liver and spleen stiffness measurements obtained with STE and STQ correlated positively with the PP (r = 0.566-0.882, all P < .001). The areas under ROC curves for L-STE, S-STE, L-STQ, and S-STQ values were 0.931 (95% confidence interval [CI], 0.847-1.000), 0.982 (95% CI, 0.956-1.000), 0.796 (95% CI, 0.680-0.912), and 0.925 (95% CI, 0.858-0.993), respectively, for PP ≥5 mmHg; 0.937 (95% CI, 0.865-1.000), 0.938 (95% CI, 0.864-1.000), 0.967 (95% CI, 0.923-1.000), and 0.960 (95% CI, 0.897-1.000), respectively, for PP ≥10 mmHg; and 0.954 (95% CI, 0.897-1.000), 0.790 (95% CI, 0.652-0.928), 0.808 (95% CI, 0.680-0.935), and 0.740 (95% CI, 0.595-0.885), respectively, for PP ≥12 mmHg.
CONCLUSIONS: STE and STQ are reliable noninvasive tools for the assessment of PHT severity, especially for PP ≥10 mmHg, in a rat model of CCl4 -induced cirrhotic PHT.