Медицинская библиотека · Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2023

Use of Sound Touch Elastography and Sound Touch Quantification for the Noninvasive Evaluation of Portal Hypertension in a Rat Model.

Dong Bingtian, Lyu Guorong, Wang Huaming, Chen Yongjian, Wei Kaipeng

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

In this study, we used the recently developed ultrasound elastography techniques sound touch elastography (STE) and sound touch quantification (STQ) to quantify portal hypertension (PHT) severity in a rat model of carbon tetrachloride (CCl4 )-induced cirrhotic PHT.

METHODS

In total, 60 rats were used. Various degrees of PHT were established. Liver and spleen stiffness were measured by STE (L-STE and S-STE, respectively) and STQ (L-STQ and S-STQ, respectively). We measured portal pressure (PP) after ultrasonographic examination. The performance of the STE and STQ parameters in the identification of PHT was evaluated using receiver operating characteristic (ROC) analyses.

RESULTS

Liver and spleen stiffness measurements obtained with STE and STQ correlated positively with the PP (r = 0.566-0.882, all P < .001). The areas under ROC curves for L-STE, S-STE, L-STQ, and S-STQ values were 0.931 (95% confidence interval [CI], 0.847-1.000), 0.982 (95% CI, 0.956-1.000), 0.796 (95% CI, 0.680-0.912), and 0.925 (95% CI, 0.858-0.993), respectively, for PP ≥5 mmHg; 0.937 (95% CI, 0.865-1.000), 0.938 (95% CI, 0.864-1.000), 0.967 (95% CI, 0.923-1.000), and 0.960 (95% CI, 0.897-1.000), respectively, for PP ≥10 mmHg; and 0.954 (95% CI, 0.897-1.000), 0.790 (95% CI, 0.652-0.928), 0.808 (95% CI, 0.680-0.935), and 0.740 (95% CI, 0.595-0.885), respectively, for PP ≥12 mmHg.

CONCLUSIONS

STE and STQ are reliable noninvasive tools for the assessment of PHT severity, especially for PP ≥10 mmHg, in a rat model of CCl4 -induced cirrhotic PHT.

Для цитирования: Dong Bingtian, Lyu Guorong, Wang Huaming, Chen Yongjian, Wei Kaipeng. Use of Sound Touch Elastography and Sound Touch Quantification for the Noninvasive Evaluation of Portal Hypertension in a Rat Model.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2023. DOI: 10.1002/jum.16172.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.