MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.thromres.2013.09.013

Медицинская библиотека · Thrombosis research · 2013

Mid-term results of self-testing of the international normalized ratio in adults with a mechanical heart valve.

Azarnoush Kasra, Dorigo Enrica, Pereira Bruno, Dauphin Claire, Geoffroy Etienne, Dauphin Nicolas, D'Ostrevy Nicola, Legault Benoit, Camilleri Lionel

Клиническое исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Commonly the frequency of international normalized ratio (INR) monitoring with a conventional laboratory test in stable patients is once a month. When using a dedicated personal device for INR assessment, the frequency may be increased to two or more times a month.

OBJECTIVE

To show that INR assessed by self-measurement at home is reliable and feasible in the mid-term and improves medical care.

PATIENTS AND

METHODS

All patients in the study on INR self-measurement (clinical trial.gov: NCT00925197), conducted between 2004 and 2007, were re-contacted for mid-term follow-up. One hundred and seventy eight out of 192 patients who participated in the study answered a questionnaire. The average follow-up time was 4.2 years (±1) for the self-measurement group and 4.9 years (±1) for the laboratory-analyzed control group.

RESULTS

Only 26 patients (group A) continued to use INR self-measurement to monitor treatment with vitamin K antagonists (VKA). The main reasons to stop INR self-measurement were its high cost and difficulty in obtaining strips. There were significantly fewer bleeding complications (p=0.04) and complications related to VKA (p=0.01) in self-measured patients compared to the control group. Feelings of security and quality of life were also significantly better (p=0.002) for self-measured patients.

CONCLUSION

Many patients with a mechanical heart valve, who self-measured INR, continue to use this method for their follow-up because of its positive effects on their health and quality of life.

Для цитирования: Azarnoush Kasra, Dorigo Enrica, Pereira Bruno, Dauphin Claire, Geoffroy Etienne, Dauphin Nicolas, D'Ostrevy Nicola, Legault Benoit, Camilleri Lionel. Mid-term results of self-testing of the international normalized ratio in adults with a mechanical heart valve.. Thrombosis research. 2013. DOI: 10.1016/j.thromres.2013.09.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.