MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-010-1900-x

Медицинская библиотека · European radiology · 2010

Ultrasound for the evaluation of femoroacetabular impingement of the cam type. Diagnostic performance of qualitative criteria and alpha angle measurements.

Buck Florian M, Hodler Juerg, Zanetti Marco, Dora Claudio, Pfirrmann Christian W A

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To develop and assess a technique to evaluate cam type femoroacetabular impingement (FAI) using ultrasound (US).

METHODS

Fifty patients (24 women, 26 men) were included (mean age: 39.1 years; age range: 16-59). US images of the anterior and anterosuperior contour of the femoral neck were obtained and analysed in 50 patients. Non-spherical shape of the head-neck junction (cam deformity), bony protuberances at the femoral neck, shape of the femoral neck (waist deficiency) and alpha angle were assessed. Magnetic resonance (MR) arthrography served as the standard of reference. Diagnostic performance and receiver operating characteristics (ROC) curves were calculated.

RESULTS

Based on MR arthrography 28 patients had cam-type FAI. On US, an anterosuperior cam deformity was seen in 40/44 patients (Reader 1/Reader 2; sensitivity 93%/89%, specificity 36%/14%). A bony protuberance anterosuperiorly in 23/13 patients (sensitivity 71%/32%, specificity 86%/82%) and an anterosuperior waist deficiency in 19/35 patients (sensitivity 25%/54%, specificity 100%/54%). Sensitivity and specificity of the other criteria were lower than 70% (average of Reader 1 & 2).

CONCLUSION

A technique to evaluate cam type FAI using US is presented. The detection of an anterosuperior cam deformity is sensitive, and presence of an anterosuperior bony protuberance is specific for cam FAI. Alpha angle measurements are not helpful in establishing the diagnosis.

Для цитирования: Buck Florian M, Hodler Juerg, Zanetti Marco, Dora Claudio, Pfirrmann Christian W A. Ultrasound for the evaluation of femoroacetabular impingement of the cam type. Diagnostic performance of qualitative criteria and alpha angle measurements.. European radiology. 2010. DOI: 10.1007/s00330-010-1900-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.