BACKGROUND

We reviewed our experience with congenital ruptured sinus of Valsalva aneurysms (RSVA) to determine patterns of early recurrence and the fate of the aortic valve (AV).

METHODS

Over a 28-year period, RSVA was identified in 34 patients, (mean age 31.6 years). Primary closure of the RSVA was performed in 10 patients, and a patch employed in 24. Aortic insufficiency was present in 24 patients. AV replacement (AVR) was performed in 5 patients; AV repair in 6.

RESULTS

Follow-up of 9.2 +/- 8.3 years (6 months to 24 years) was complete in all but 2 patients. Five early fistula recurrences (in 4 patients) correlated with primary rather than patch closure (p < 0.03). Kaplan-Meier survival at 10 years is 90 +/- 7%. Freedom from reoperative AVR at 10 years is 83 +/- 9%. Late AVR was performed in 6 patients for progressive aortic insufficiency due to bicuspid valve (n = 3), cusp disease of affected sinus (n = 2), or aortic root dilatation (n = 2).

CONCLUSIONS

Patch closure of the RSVA should be routinely employed. A bicuspid valve may be associated with the late need for AVR.

Для цитирования: Azakie A, David T E, Peniston C M, Rao V, Williams W G. Ruptured sinus of valsalva aneurysm: early recurrence and fate of the aortic valve.. The Annals of thoracic surgery. 2000. DOI: 10.1016/s0003-4975(00)01734-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.