Predictors, Morbidity, and Costs Associated with Pneumothorax during Electronic Cardiac Device Implantation.

Kotter John, Lolay Georges, Charnigo Richard, Leung Steve, McKibbin Christopher, Sousa Matthew, Jimenez Luis, Gurley John, Biase Luigi DI, Natale Andrea, Smyth Susan, Darrat Yousef, Morales Gustavo, Elayi Claude S

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Pneumothorax (PTX) is a major cause of morbidity associated with cardiac implantable electronic devices (CIEDs). We sought to evaluate predictors of PTX at our centers during CIED implantations, including the venous access technique utilized, as well as to determine morbidity and costs associated with PTX.

METHODS

We reviewed records of all patients undergoing cardiac device implant or revision with new venous access at our institutions between 2008 and 2014. Common demographic and procedure characteristics were collected including age, sex, body mass index (BMI), comorbidities, and method of venous access (axillary vein vs classic proximal subclavian vein technique).

RESULTS

We identified 1,264 patients who met criteria for our analysis, with a total of 21 PTX cases during CIED implantation. The strongest predictor for PTX was the venous access strategy: 0 of 385 (0%) patients with axillary vein approach versus 21 of 879 (2.4%) with traditional subclavian vein approach, P = 0.0006. Additional predictors of PTX included advanced age, female sex, low BMI, and a new device implant (vs device upgrade). The occurrence of PTX was associated with increased length of stay: 3.0 days (median; interquartile range [IQR] 3) versus 1.0 day (median; IQR: 1), P = 0.0001, with a cost increase of 361.4%.

CONCLUSION

An axillary vein vascular access strategy was associated with greatly reduced risk of iatrogenic PTX versus the traditional subclavian approach for CIED placement. Similarly, device upgrade with patent vascular access carried less risk of PTX compared to new device implantation. PTX occurrence significantly prolonged hospitalization and increased costs.

Для цитирования: Kotter John, Lolay Georges, Charnigo Richard, Leung Steve, McKibbin Christopher, Sousa Matthew, Jimenez Luis, Gurley John, Biase Luigi DI, Natale Andrea, Smyth Susan, Darrat Yousef, Morales Gustavo, Elayi Claude S. Predictors, Morbidity, and Costs Associated with Pneumothorax during Electronic Cardiac Device Implantation.. Pacing and clinical electrophysiology : PACE. 2016. DOI: 10.1111/pace.12901.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.