MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.medengphy.2014.06.020

Медицинская библиотека · Medical engineering & physics · 2014

Automatic modeling of pectus excavatum corrective prosthesis using artificial neural networks.

Rodrigues Pedro L, Rodrigues Nuno F, Pinho A C M, Fonseca Jaime C, Correia-Pinto Jorge, Vilaça João L

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Pectus excavatum is the most common deformity of the thorax. Pre-operative diagnosis usually includes Computed Tomography (CT) to successfully employ a thoracic prosthesis for anterior chest wall remodeling. Aiming at the elimination of radiation exposure, this paper presents a novel methodology for the replacement of CT by a 3D laser scanner (radiation-free) for prosthesis modeling. The complete elimination of CT is based on an accurate determination of ribs position and prosthesis placement region through skin surface points. The developed solution resorts to a normalized and combined outcome of an artificial neural network (ANN) set. Each ANN model was trained with data vectors from 165 male patients and using soft tissue thicknesses (STT) comprising information from the skin and rib cage (automatically determined by image processing algorithms). Tests revealed that ribs position for prosthesis placement and modeling can be estimated with an average error of 5.0 ± 3.6mm. One also showed that the ANN performance can be improved by introducing a manually determined initial STT value in the ANN normalization procedure (average error of 2.82 ± 0.76 mm). Such error range is well below current prosthesis manual modeling (approximately 11 mm), which can provide a valuable and radiation-free procedure for prosthesis personalization.

Для цитирования: Rodrigues Pedro L, Rodrigues Nuno F, Pinho A C M, Fonseca Jaime C, Correia-Pinto Jorge, Vilaça João L. Automatic modeling of pectus excavatum corrective prosthesis using artificial neural networks.. Medical engineering & physics. 2014. DOI: 10.1016/j.medengphy.2014.06.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.