MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Revista medica del Instituto Mexicano del Seguro Social · 2022

[Levosimendan for preventing low output syndrome in pediatric patients with correction of tetralogy of Fallot].

Gutiérrez-Riveroll Karla Itzel, Mejía Picazo Héctor Jorge, Dosta-Herrera Juan José

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Tetralogy of Fallot is one of the most frequent cyanotic heart diseases in our country, occupying the second place reported by the national health program 2007- 2012 and its prevalence is around 11%. Patients undergoing correction for tetralogy of Fallot are considered patients with a prolonged ischemic time and a high risk of presenting low cardiac output syndrome.

OBJECTIVE

To compare levosimendan with milrinone to prevent low cardiac output syndrome in patients undergoing tetralogy of Fallot correction.

MATERIAL AND

METHODS

Randomized controlled open, prospective, longitudinal and comparative clinical trial. The sample size consisted of 19 patients, with a 95% confidence level. Group 1: levosimendan 0.1 mcg/kg/min from anesthetic induction. Group 2: conventional management with milrinone 0.5 mcg/kg/min.

RESULTS

When comparing the final measurements, it can be observed that the mean arterial pressure of the intervention group (levosimendan) was statistically significant (p = 0.04), both in the intraoperative measurement and in the final measurement. When comparing uresis, we found that the intervention group had a greater amount of uresis (p = 0.03). Regarding lactate, both in the intraoperative measurement (p = 0.002) and in the final measurement (p = 0.02), a lower amount was found in the intervention group.

CONCLUSIONS

The results in favor of the use of levosimendan were reported, demonstrating the prevention of low cardiac output syndrome.

Для цитирования: Gutiérrez-Riveroll Karla Itzel, Mejía Picazo Héctor Jorge, Dosta-Herrera Juan José. [Levosimendan for preventing low output syndrome in pediatric patients with correction of tetralogy of Fallot].. Revista medica del Instituto Mexicano del Seguro Social. 2022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.