MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000029408

Медицинская библиотека · Medicine · 2022

Investigator initiated clinical trial to validate usefulness of specific system for endoscopic ultrasound guided hepaticogastrostomy (HG01) in malignant biliary obstruction (HG01).

Itonaga Masahiro, Kitano Masayuki, Isayama Hiroyuki, Takenaka Mamoru, Ogura Takeshi, Yamashita Yasunobu, Fujisawa Toshio, Minaga Kosuke, Okuda Atsushi, Shimokawa Toshio

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

INTRODUCTION

Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is a novel drainage option for patients with an inaccessible papilla. Although EUS-HGS has clinical benefits in patients for whom endoscopic retrograde cholangiopancreatography (ERCP) has failed, the rates of adverse events (AEs) associated with EUS-HGS, such as bile peritonitis and stent migration, are higher than for other procedures. The development of a dedicated system for EUS-HGS is therefore desirable to reduce the rate of AEs. We developed a dedicated system for EUS-HGS (HG01 system) which is composed of a 19-gauge needle, 0.025-inch guidewire, a thin delivery system for tract dilation, and an antimigration metal stent. This study is designed to evaluate the efficacy and safety of EUS-HGS using the HG01 system in malignant biliary obstruction.

METHODS/

DESIGN

This is a single-arm multicenter prospective study involving 40 patients across six tertiary centers in Japan. Patients with an unresectable malignant biliary obstruction in whom biliary drainage with ERCP failed, is not possible, or is very difficult will be registered in the study. The primary endpoint is the clinical success rate. The secondary endpoints are the technical success rate, procedure-related AE rate, procedure time, procedure success rate using only the HG01 system, stent patency rate, re-intervention success rate, re-intervention method, survival rate, and distance of movement of the stent position.

DISCUSSION: We expect use of the HG01 system to reduce the rate of AEs during EUS-HGS, especially bile leakage and stent migration. If the efficacy and safety of EUS-HGS using the HG01 system is confirmed in the present study, it is likely to be considered the first-choice device for use during EUS-HGS.

Для цитирования: Itonaga Masahiro, Kitano Masayuki, Isayama Hiroyuki, Takenaka Mamoru, Ogura Takeshi, Yamashita Yasunobu, Fujisawa Toshio, Minaga Kosuke, Okuda Atsushi, Shimokawa Toshio. Investigator initiated clinical trial to validate usefulness of specific system for endoscopic ultrasound guided hepaticogastrostomy (HG01) in malignant biliary obstruction (HG01).. Medicine. 2022. DOI: 10.1097/md.0000000000029408.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.