BMC pulmonary medicine · 2022
Relationship between concavity of the flow-volume loop and small airway measures in smokers with normal spirometry.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Alowiwi Hooria, Watson Stella, Jetmalani Kanika, Thamrin Cindy, Johns David P, Walters E Haydn, King Gregory G
Аннотация
BACKGROUND: There is increasing evidence of small airway abnormalities in smokers despite normal spirometry. The concavity in the descending limb of the maximum expiratory flow curve (MEFV) is a recognised feature of obstruction and can provide information beyond FEV1, and potentially early smoking-related damage. We aimed to evaluate concavity measures compared to known small airway measurements.
METHODS: Eighty smokers with normal spirometry had small airway function assessed: multiple breath nitrogen washout (MBNW) from which ventilation heterogeneity in the diffusion-dependent acinar (Sacin) and convection-dependent conductive (Scond) airways were assessed, and impulse oscillometry system (IOS) from which respiratory resistance and reactance at 5 Hz (R5 and X5) were measured. Concavity measures were calculated from the MEFV, partitioned into global and peripheral concavity.
RESULTS: We found abnormal peripheral and global concavity as well as acinar ventilation heterogeneity are common in "normal" smokers. Concavity measures were not related to either MBNW or IOS measurements.
CONCLUSION: Abnormalities in concavity indices and MBNW or oscillometry parameters are common in smokers despite normal spirometry. However, these measures likely reflect different mechanisms of peripheral airway dysfunction.
METHODS: Eighty smokers with normal spirometry had small airway function assessed: multiple breath nitrogen washout (MBNW) from which ventilation heterogeneity in the diffusion-dependent acinar (Sacin) and convection-dependent conductive (Scond) airways were assessed, and impulse oscillometry system (IOS) from which respiratory resistance and reactance at 5 Hz (R5 and X5) were measured. Concavity measures were calculated from the MEFV, partitioned into global and peripheral concavity.
RESULTS: We found abnormal peripheral and global concavity as well as acinar ventilation heterogeneity are common in "normal" smokers. Concavity measures were not related to either MBNW or IOS measurements.
CONCLUSION: Abnormalities in concavity indices and MBNW or oscillometry parameters are common in smokers despite normal spirometry. However, these measures likely reflect different mechanisms of peripheral airway dysfunction.