Reproducibility of circumpapillary retinal nerve fiber layer measurements using handheld optical coherence tomography in sedated children.

Avery Robert A, Cnaan Avital, Schuman Joel S, Chen Chieh-Li, Glaug Natalie C, Packer Roger J, Quinn Graham E, Ishikawa Hiroshi

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

PURPOSE: To determine the intra- and intervisit reproducibility of circumpapillary retinal nerve fiber layer (RNFL) measures using handheld optical coherence tomography (OCT) in sedated children.

DESIGN

Prospective cross-sectional and longitudinal study.

METHODS

Children undergoing sedation for a clinically indicated magnetic resonance imaging for an optic pathway glioma and/or neurofibromatosis type 1 (NF1) had multiple 6 × 6 mm volumes (isotropic 300 × 300 or nonisotropic 1000 × 100 samplings) acquired over the optic nerve. Children with 2 handheld OCT sessions within 6 months were included in the intervisit cohort. The intra- and intervisit coefficient of variation (CV) and intraclass correlation coefficient (ICC) were calculated for the average and anatomic quadrant circumpapillary RNFL thickness.

RESULTS

Fifty-nine subjects (mean age 5.1 years, range 0.8-13.0 years) comprised the intravisit cohort and 29 subjects (mean age 5.7 years, range 1.8-12.7 years) contributed to the intervisit cohort. Forty-nine subjects had an optic pathway glioma and 10 subjects had NF1 without an optic pathway glioma. The CV was comparable regardless of imaging with an isotropic and nonisotropic volume in both the intra- and intervisit cohorts. The average circumpapillary RNFL demonstrated the lowest CV and highest ICC compared to the quadrants. For the intervisit cohort, the average ICC was typically higher while the CV was typically lower, but not statistically different compared to the other quadrants.

DISCUSSION: Circumpapillary RNFL measures acquired with handheld OCT during sedation demonstrate good intra- and intervisit reproducibility. Handheld OCT has the potential to monitor progressive optic neuropathies in young children who have difficulty cooperating with traditional OCT devices.

Для цитирования: Avery Robert A, Cnaan Avital, Schuman Joel S, Chen Chieh-Li, Glaug Natalie C, Packer Roger J, Quinn Graham E, Ishikawa Hiroshi. Reproducibility of circumpapillary retinal nerve fiber layer measurements using handheld optical coherence tomography in sedated children.. American journal of ophthalmology. 2014. DOI: 10.1016/j.ajo.2014.06.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.