BACKGROUND

It has previously been suggested that significant dilatation of the coronary sinus can contribute to left ventricular inflow obstruction and is amenable to surgical correction. The purpose of this study was to review our experience with this rare condition.

METHODS

Since 1995, 6 patients have undergone coronary sinus reduction for concerns of obstruction with other concomitant intracardiac repairs. Preoperative echocardiography identified a significantly dilated left superior vena cava to the coronary sinus in 5 patients (83%) and an abnormal mitral valve in 4 patients (67%); these resulted in abnormal Doppler inflow patterns. Preoperative cardiac catheterization was performed in 5 patients and revealed increased atrial "a" waves, with a gradient to the left ventricular end-diastolic pressure in each case. At the time of surgery, coronary sinus angioplasty was performed in all patients.

RESULTS

There were no deaths, and there was no major morbidity. Follow-up imaging revealed no significant left ventricular inflow obstruction in any patient.

CONCLUSIONS

We conclude that dilatation of the coronary sinus can become hemodynamically significant and that coronary sinus angioplasty is a safe and effective technique.

Для цитирования: Dibardino Daniel J, Fraser Charles D, Dickerson Heather A, Heinle Jeffrey S, McKenzie E Dean, Kung Grace. Left ventricular inflow obstruction associated with persistent left superior vena cava and dilated coronary sinus.. The Journal of thoracic and cardiovascular surgery. 2004. DOI: 10.1016/j.jtcvs.2003.07.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.