MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.injury.2020.04.057

Медицинская библиотека · Injury · 2020

Evaluation of the effects of using 3D - patient specific models of displaced intra - articular calcaneal fractures in surgery.

Ozturk Anil Murat, Ozer Mehmet Asim, Suer Onur, Derin Okan, Govsa Figen, Aktuglu Kemal

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

It was aimed to compare conventional surgery and three-dimensional (3D) model-assisted surgery used in the treatment of calcaneal fractures.

MATERIALS &

METHODS

A total of 37 patients with unilateral calcaneal fractures were randomly divided into two groups as a conventional surgery group (n: 19) and a 3D model-assisted surgery group (n: 18). The preoperative, postoperative and last follow up angles of the Bohler and Gissane, calcaneal width and facet height were measured. The duration of the operation, blood loss volume, fluoroscopy usage, instrumentation time for both groups were recorded. Finally, the follow-up AOFAS scores were evaluated. A questionnaire was used to determine the perceptions of the resident doctors about the 3D model.

RESULTS

The duration of the operation, blood loss volume, fluoroscopy usage, instrumentation time for 3D model-assisted surgery group were 83.3 ± 4.6 minutes, 83.6 ± 4.6 ml, 6.8 ± 1.4 times and 13.0 ± 0.8 weeks, and as for conventional group they were 130.0 ± 5.8 minutes, 105.1 ± 5.6 minutes, 11.7 ± 1.5 ml, 22.2 ± 2.4 times and 13.3 ± 0.8 weeks, respectively (p < 0.0001). The both groups significantly restored Bohler angle, Gissane angle, calcaneal width and calcaneal facet height after operation (p < 0.0001). The 3D model-assisted group was significantly more succesful in restoration and protection of achieved correction of calcanel facet height (p < 0.0001). The difference was determined among the groups at the final follow-up examination with respect to the amount of change according the values achieved post-op. were significant in Bohler angle (p < 0.001), calcaneal facet height (p < 0.0001) and calcaneal widht (p = 0.017). There was no significant difference between AOFAS scores of the two groups at last follow-up. Resident doctors exhibited high scores of overall satisfaction with the use of a 3D printing model.

CONCLUSIONS

Compared to the conventional group, the 3D model-assisted group provide successful intervention and reduce operation, instrumentation time and the fluoroscopy usage with less blood loss. Performing 3D-assisted surgery helps the quality of reduction during the surgery and stability of internal fixation to protect achieved reduction at follow-up more succesfully.

Для цитирования: Ozturk Anil Murat, Ozer Mehmet Asim, Suer Onur, Derin Okan, Govsa Figen, Aktuglu Kemal. Evaluation of the effects of using 3D - patient specific models of displaced intra - articular calcaneal fractures in surgery.. Injury. 2020. DOI: 10.1016/j.injury.2020.04.057.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.