DOI 10.1016/j.arth.2024.06.022
Muscle Activity and Biomechanics While Descending a Staircase After Total Knee Arthroplasty: A Study Comparing Different Posterior Stabilized and Medial Ball-and-Socket Designs.
Аннотация
BACKGROUND
Many patients report more difficulty when descending stairs compared to level walking after total knee arthroplasty (TKA). Different implant designs can affect knee biomechanics and muscle activity during gait, but their effect during stair descent is unclear. The purpose of this study was to evaluate knee biomechanics and muscle activations of quadriceps, hamstrings, and gastrocnemius muscles during a stair descent task in patients who underwent TKA with either a posterior stabilized (PS) or medial ball-and-socket (MBS) implant and to compare them to a group of healthy controls.
METHODS
There were 28 TKA patients who were randomized to either an MBS (n = 14) or PS (n = 14) implant and were compared with 14 controls. Patients visited the biomechanics lab approximately 12 months after TKA, where knee biomechanics and muscle activity were measured as they descended a 3-step staircase.
RESULTS
Compared to the MBS and control groups, the PS group descended the stairs with a reduced knee flexion angle and greater hamstring muscle activation throughout single limb support. Knee joint moments and power were similar between the MBS and PS groups, but neither reached the level of the control group.
CONCLUSIONS
Lower knee flexion angles and increased hamstring muscle activity indicated that the PS group descended the stairs with a stiffer knee gait pattern than the MBS group. The MBS implant design may provide additional stability as patients require less muscle activity than the PS group.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.