m+Medelevator.RU
← Поиск публикаций
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2006

Transcatheter closure of coronary artery fistulae using the Amplatzer Duct Occluder.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Behera Sarina K, Danon Saar, Levi Daniel S, Moore John W

Аннотация

OBJECTIVE: The aim of this study is to report our experience using the Amplatzer Duct Occluder (ADO) for occlusion of significant coronary artery fistulae (CAF).

BACKGROUND: Transcatheter closure of CAF with coils is well described. Use of newer devices may offer advantages such as improved control of device placement, use of a single instead of multiple devices, and high rates of occlusion.

METHODS: A retrospective review of all patients catheterized for CAF from July 2002 through August 2005 was performed.

RESULTS: Thirteen patients with CAF underwent cardiac catheterization, of which a total of 6 patients had ADO placement in CAF (age, 21 days to 56 years; median age, 4.3 years and weight, 3.8 kg to 74.6 kg; median weight, 13.3 kg). An arteriovenous wire loop was used to advance a long sheath antegrade to deploy the ADO in the CAF. Immediate and short-term outcomes (follow-up, 3 months to 14 months; median follow-up, 8.5 months) demonstrated complete CAF occlusion in 5 patients and minimal residual shunt in 1 patient (who had resolution of right atrial and right ventricular enlargement). On follow-up clinical evaluation, all 6 patients had absence of fistula-related murmurs, and 2 previously symptomatic patients had resolution of congestive heart failure symptoms. Early complications included transient palpitations and atrial arrhythmia in the 2 oldest patients (52 and 56 years old).

CONCLUSIONS: Use of the ADO is applicable for transcatheter closure of significant CAF. Advantages of using the ADO include the antegrade approach, use of a single device, and effective CAF occlusion.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты