The Journal of thoracic and cardiovascular surgery · 2007

Intraoperative device closure of secundum atrial septal defect with a right anterior minithoracotomy in 100 patients.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hongxin Li, Wenbin Guo, Lijun Sheng, Zhengjun Wang, Hao Liang, Chengwei Zou, Liang Du, Guidao Yuan

Аннотация

OBJECTIVE: This study aims to report our experience using intraoperative device closure of secundum atrial septal defects and to evaluate the feasibility and clinical outcome of this technique.

METHODS: One hundred patients with secundum atrial septal defects (mean age, 29 +/- 16 years; age range, 5-71 years; mean weight, 54 +/- 18 kg; weight range, 16-94 kg) underwent intraoperative device closure through a right minithoracotomy without cardiopulmonary bypass and fluoroscopy. A 2.5- to 3-cm parasternal or submammary incision was made in the right third or fourth intercostal space. Exposed with a miniretractor, a specially designed plastic sheath loaded with the device was inserted through the purse-string sutures placed on the right atrium. Under transesophageal echocardiographic guidance, it was advanced through the atrial septal defect into the left atrium, and the device was deployed in place.

RESULTS: The procedure was successful in all patients, including 5 patients with double atrial septal defects. The maximum diameter of the atrial septal defect ranged from 5 to 37 mm (mean, 21 +/- 7 mm). There were 61 patients with an atrial septal defect diameter of more than 20 mm, 16 of them with a diameter of more than 30 mm. The mean size of implanted devices was 25 +/- 7 mm (range, 8-36 mm). Residual shunts were found in 9 (9%) patients immediately after the operation. The complete occlusion rate was 95% at discharge, 99% at the 3-month follow-up, and 100% at the 1-year follow-up. There were no other late complications during the follow-up period.

CONCLUSIONS: Intraoperative device closure is a safe, cost-effective, cosmetic, and less-invasive operation of most secundum atrial septal defects. Follow-up results are encouraging. It can be considered an acceptable alternative to transcatheter closure or surgical repair.