MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12917-025-05120-0

Медицинская библиотека · BMC veterinary research · 2025

Validation of a smart textile device for long-duration heart rate variability and detection of physiological arrhythmias in resting horses.

McCrae Persephone, Spong Hannah, Moorehead Jordyn, Pearson Wendy

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

BACKGROUND

A smart textile device has been developed for the recording of electrocardiograms (ECGs) in horses; however, the utility of this device for long-duration heart rate variability (HRV) monitoring and detection of physiological arrhythmias is unknown. Therefore, the objective of this study was to validate a smart textile device for HRV over long durations (6 h) in resting horses. ECGs were recorded simultaneously via the Myant Skiin Equine textile device and a reference device (Televet 100) in 12 horses. ECGs were evaluated by a blinded observer for arrhythmias, and HRV metrics were calculated. Agreement between the two devices was assessed via Bland‒Altman analysis and Lin's concordance correlation coefficient.

RESULTS

Substantial to perfect agreement was found for all the HRV metrics. Physiological arrhythmias were detected in all the recordings from the twelve horses. Small biases and substantial to perfect agreement were found between the two devices for sinoatrial blocks (ρc = 0.99), sinus pauses (ρc = 0.96), sinus arrhythmias (ρc = 0.96), sinus tachycardia (ρc = 0.99), and 2nd degree atrioventricular blocks (ρc = 1.0).

CONCLUSIONS

This study demonstrates that a smart textile system is a practical alternative to the standard telemetric device for long-duration assessment of HRV and the detection of physiological arrhythmias in healthy, resting horses.

Для цитирования: McCrae Persephone, Spong Hannah, Moorehead Jordyn, Pearson Wendy. Validation of a smart textile device for long-duration heart rate variability and detection of physiological arrhythmias in resting horses.. BMC veterinary research. 2025. DOI: 10.1186/s12917-025-05120-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.