Evaluation of between-methods agreement of extracellular water measurements in adults and children.
Оценочное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Silva Analiza M, Heymsfield Steven B, Gallagher Dympna, Albu Jeanine, Pi-Sunyer Xavier F, Pierson Richard N, Wang Jack, Heshka Stanley, Sardinha Luis B, Wang Zimian
Аннотация
BACKGROUND: Extracellular water (ECW), a relevant molecular level component for clinical assessment, is commonly obtained by 2 methods that rely on assumptions that may not be possible to test at the time the measurements are made.
OBJECTIVE: The aim of the current study was to evaluate the degree of agreement between ECW assessment by the sodium bromide dilution (ECW(NaBr)) and total body potassium (TBK; whole-body (40)K counting) to total body water (TBW; isotope dilution) methods (ECW(TBK-TBW)) in an ethnically mixed group of children and adults.
DESIGN: ECW was measured with the ECW(NaBr) and ECW(TBK-TBW) methods in 526 white and African American males and females (86 nonobese children, 193 nonobese adults, and 247 obese adults). Fat mass was assessed with dual-energy X-ray absorptiometry. Multiple regression analysis was used to examine the variables related to between-ECW method differences.
RESULTS: Significant but generally small group mean (+/-SD) differences in ECW were found in the obese adults (1.28 +/- 2.54 kg) and children (-0.71 +/- 1.78 kg). The magnitude of the differences was related to mean ECW in obese adults, children, and nonobese adults, and the relations between these variables were modified by sex for nonobese adults. ECW differences were also dependent on age, weight, sex, and race or on interactions between these variables.
CONCLUSIONS: Overall, although good between-method agreement was found across the 3 groups, the degree of agreement varied according to subject characteristics, particularly at the extremes of ECW and body weight. We advance a possible mechanism that may link subject characteristics with the degree of agreement between ECW measurement methods and their underlying assumptions.
OBJECTIVE: The aim of the current study was to evaluate the degree of agreement between ECW assessment by the sodium bromide dilution (ECW(NaBr)) and total body potassium (TBK; whole-body (40)K counting) to total body water (TBW; isotope dilution) methods (ECW(TBK-TBW)) in an ethnically mixed group of children and adults.
DESIGN: ECW was measured with the ECW(NaBr) and ECW(TBK-TBW) methods in 526 white and African American males and females (86 nonobese children, 193 nonobese adults, and 247 obese adults). Fat mass was assessed with dual-energy X-ray absorptiometry. Multiple regression analysis was used to examine the variables related to between-ECW method differences.
RESULTS: Significant but generally small group mean (+/-SD) differences in ECW were found in the obese adults (1.28 +/- 2.54 kg) and children (-0.71 +/- 1.78 kg). The magnitude of the differences was related to mean ECW in obese adults, children, and nonobese adults, and the relations between these variables were modified by sex for nonobese adults. ECW differences were also dependent on age, weight, sex, and race or on interactions between these variables.
CONCLUSIONS: Overall, although good between-method agreement was found across the 3 groups, the degree of agreement varied according to subject characteristics, particularly at the extremes of ECW and body weight. We advance a possible mechanism that may link subject characteristics with the degree of agreement between ECW measurement methods and their underlying assumptions.