m+Medelevator.RU
← Поиск публикаций
Hepatology communications · 2022

High reproducibility of spleen stiffness measurement by vibration-controlled transient elastography with a spleen-dedicated module.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rigamonti Cristina, Cittone Micol Giulia, Manfredi Giulia Francesca, Sorge Andrea, Moia Riccardo, Patriarca Andrea, Donato Maria Francesca, Gaidano Gianluca, Pirisi Mario, Fraquelli Mirella

Аннотация

Spleen stiffness measurement (SSM) by vibration-controlled transient elastography (VCTE) is a noninvasive technique for estimating portal hypertension in patients with chronic liver disease (CLD), with its reproducibility yet to be established and its feasibility still unknown beyond CLD. We have studied 420 participants from two tertiary referral centers for liver diseases (Novara, Milan): 297 patients with CLD (32% with cirrhosis) of different etiology (Group A), 63 Philadelphia-negative myeloproliferative neoplasms (Group B), and 60 heathy volunteers (Group C). All underwent SSM by VCTE with a spleen-dedicated module (SSM@100 Hz) and liver stiffness measurement (LSM), blindly performed by 2 different operators. In total, 1680 VCTE examinations for SSM were performed (1000 in Novara, 680 in Milan), with an overall 3.2% failure rate. Median SSM was 26.5 kPa (interquartile range [IQR] 20.0-42.3) in Group A, 26.3 kPa (IQR 22.3-33.6) in Group B, and 16.1 kPa (IQR 14.6-18.7) in Group C. In Group A, the median LSM was 6.8 kPa (IQR 4.9-11.3) in Novara and 8.3 kPa (IQR 7.1-10.8) in Milan, the proportion of patients with cirrhosis being 34% in Novara and 31% in Milan. The Group A interobserver agreement ICC was 0.90 (0.88-0.92), significantly lower in the absence of splenomegaly (ICC 0.87 vs. 0.91) and in absence of cirrhosis (ICC 0.84 vs. 0.90); overweight slightly, but not significantly reduced the interobserveragreement. The intra-observer agreement ICC ranged from 0.91 to 0.96 for the four operators. The Group B interobserver agreement ICC was 0.90 (0.83-0.94). In conclusion, SSM measured by the new spleen-dedicated VCTE module is a feasible, reliable, and highly reproducible tool in patients with CLD and hematological disorders, and in healthy volunteers.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты