m+Medelevator.RU
← Поиск публикаций
American journal of physiology. Regulatory, integrative and comparative physiology · 2008

Ventilatory responses to acute and chronic hypoxia are altered in female but not male Paskin-deficient mice.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Delhaas Tammo, Kroon Wilco, Decaluwe Wim, Rubbens Mirjam, Bovendeerd Peter, Arts Theo

Аннотация

In 1926, the famous American pediatric cardiologist, Dr. Helen B. Taussig, observed that in situs inversus totalis (SIT) main gross anatomical structures and the deep muscle bundles of the ventricles were a mirror image of the normal structure, while the direction of the superficial muscle bundles remained unchanged (H. B. Taussig, Bull Johns Hopkins Hosp 39: 199-202, 1926). She and we wondered about the implication of this observation for left ventricular (LV) deformation in SIT. We used magnetic resonance tagging to obtain information on LV deformation, rotation, and torsion from a series of tagged images in five evenly distributed, parallel, short-axis sections of the heart of nine controls and eight persons with SIT without other structural (cardiac) defect. In the controls, during ejection, the apex rotated counterclockwise with respect to the base, when looking from the apex. Furthermore, the base-to-apex gradient in rotation (torsion) was negative and similar at all longitudinal levels of the LV. In SIT hearts, torsion was positive near the base, indicating mirrored myofiber orientations compared with the normal LV. Contrary to expectations, torsion in the apical regions of SIT LVs was as in normal ones, reflecting a normal internal myocardial architecture. The transition zone with zero torsion, found between the apex and base, suggests that the heart structure in SIT is essentially different from that in the normal heart. This provides a unique possibility to study regulatory mechanisms for myocardial fiber orientation and mechanical load, which has been dealt with in the companion paper by Kroon et al.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты