Pacemaker system failure and other events in children with surgically induced heart block.

McGrath L B, Gonzalez-Lavin L, Morse D P, Levett J M

СтатьяПеревод в очереди

Аннотация

Of 1,193 consecutive pediatric (less than 18 years) patients undergoing intracardiac repair from 1975 to 1984, 38 (3.2%) developed surgically induced complete heart block and were treated by permanent pacemaker implantation. Anomalies included complete atrioventricular septal defect = 9 (24%), simple ventricular septal defect = 9 (24%), atrioventricular discordant connection = 8 (212), tetralogy of Fallot = 7 (182), and other complex anomalies = 5 (13%). There were no hospital deaths. follow-up was 100% complete. There were six late deaths = 16%. Actuarial survival was 79 + 9% at 10 years. None of the late deaths were related to disturbance of cardiac rhythm or pacemaker system failure. Twelve patients (32%), required 27 reoperations for various types of pacemaker system failure. Indications for reoperation included: lead failure (44%). Pulse generator failure (44%), and wound sepsis (12%). Actuarial freedom from any pacemaker related reoperation was 50 + 16% at 48 months and 25 + 15% at 96 months. Only first reoperation was found to be an incremental risk factor for subsequent reoperation (p = 0.03). Surgical heart block has been neutralized as a risk factor for hospital death after repair of congenital cardiac defects. The risk of the development of surgical heart block now approaches zero, as indicated by a decreased incidence (1 of 401 = 0.25%) in our institution from 1985 to 1987, as compared to the era 1975 to 1984 (p = 0.001).

Для цитирования: McGrath L B, Gonzalez-Lavin L, Morse D P, Levett J M. Pacemaker system failure and other events in children with surgically induced heart block.. Pacing and clinical electrophysiology : PACE. 1988. DOI: 10.1111/j.1540-8159.1988.tb03970.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.