m+Medelevator.RU
← Поиск публикаций
Blood pressure · 2018

Evidence-based proposal for the number of ambulatory readings required for assessing blood pressure level in research settings: an analysis of the IDACO database.

СтатьяМногоцентровое исследованиеРандомизированное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yang Wen-Yi, Thijs Lutgarde, Zhang Zhen-Yu, Asayama Kei, Boggia José, Hansen Tine W, Ohkubo Takayoshi, Jeppesen Jørgen, Stolarz-Skrzypek Katarzyna, Malyutina Sofia, Casiglia Edoardo, Nikitin Yuri, Li Yan, Wang Ji-Guang, Imai Yutaka, Kawecka-Jaszcz Kalina, O'Brien Eoin, Staessen Jan A, International Database; on Ambulatory blood pressure in relation to Cardiovascular Outcomes (IDACO) Investigators

Аннотация

BACKGROUND: Guidelines on the required number of ambulatory blood pressure (ABP) readings focus on individual patients. Clinical researchers often face the dilemma of applying recommendations and discarding potentially valuable information or accepting fewer readings.

METHODS: Starting from ABP recordings with ≥30/≥10 awake/asleep readings in 4277 participants enrolled in eight population studies in the International Database on Ambulatory Blood Pressure in Relation to Cardiovascular Outcomes (IDACO), we randomly selected a certain number of readings (from 30 to 1 awake and 10 to 1 asleep readings) at a time over 1000 bootstraps at each step. We evaluated: (i) concordance of the ABP level; (ii) consistency of the cross-classification based on office blood pressure and ABP; and (iii) accuracy in predicting cardiovascular complications. For each criterion, we fitted a regression line joining data points relating outcome to the number of readings covering the ranges of 30-20/10-7 for awake/asleep readings.

RESULTS: Reducing readings widened the SD of the systolic/diastolic differences between full (reference) and selected recordings from 1.7/1.2 (30 readings) to 14.3/10.3 mm Hg (single reading) during wakefulness, and from 1.9/1.4 to 10.3/7.7 mm Hg during sleep; lowered the κ statistic from 0.94 to 0.63, and decreased the hazard ratio associated with 10/5 mm Hg increments in systolic/diastolic ABP from 1.21/1.14 to 1.06/1.04 during wakefulness and from 1.26/1.17 to 1.14/1.08 during sleep. The first data points falling off these regression lines during wakefulness/sleep corresponded to 8/3 and 8/4 readings for criteria (i) and (iii) and to 5 awake readings for criterion (ii).

CONCLUSIONS: 24-h ambulatory recordings with ≥8/≥4 awake/asleep readings yielded ABP levels similar to recordings including the guideline-recommended ≥20/≥7 readings. These criteria save valuable data in a research setting, but are not applicable to clinical practice.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты