MedElevator Войти в исследования
← Поиск публикаций

DOI 10.36416/1806-3756/e20210290

Медицинская библиотека · Jornal brasileiro de pneumologia : publicacao oficial da Sociedade Brasileira de Pneumologia e Tisilogia · 2022

Intra-breath oscillometry for the evaluation of lung function in children and adolescents with a history of preterm birth.

Accorsi Bruna Freire, Friedrich Frederico Orlando, Corso Andréa Lúcia, Rosa Juliana Pontes da, Jones Marcus Herbert

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess respiratory system impedance (Zrs) and spirometric parameters in children and adolescents with and without a history of preterm birth.

METHODS

We evaluated a sample of 51 subjects between 11 and 14 years of age: 35 who had a history of preterm birth (preterm group) and 16 who had been born at term (full-term group). Lung function was measured by spirometry, spectral oscillometry, and intra-breath oscillometry.

RESULTS

Neither spirometry nor spectral oscillometry revealed any statistically significant differences between the preterm and full-term groups. However, intra-breath oscillometry demonstrated significant differences between the two groups in terms of the change in resistance, reactance at end-inspiration, and the change in reactance (p < 0.05 for all).

CONCLUSIONS

Our findings suggest that abnormalities in Zrs persist in children and adolescents with a history of preterm birth and that intra-breath oscillometry is more sensitive than is spectral oscillometry. Larger studies are needed in order to validate these findings and to explore the impact that birth weight and gestational age at birth have on Zrs later in life.

Для цитирования: Accorsi Bruna Freire, Friedrich Frederico Orlando, Corso Andréa Lúcia, Rosa Juliana Pontes da, Jones Marcus Herbert. Intra-breath oscillometry for the evaluation of lung function in children and adolescents with a history of preterm birth.. Jornal brasileiro de pneumologia : publicacao oficial da Sociedade Brasileira de Pneumologia e Tisilogia. 2022. DOI: 10.36416/1806-3756/e20210290.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.