m+Medelevator.RU
← Поиск публикаций
Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies · 2017

Nebulized Fluticasone for Preventing Postextubation Stridor in Intubated Children: A Randomized, Double-Blind Placebo-Controlled Trial.

СтатьяРандомизированное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Prasertsan Pharsai, Nakju Duangjai, Lertbunrian Rojjanee, Chantra Marut, Anantasit Nattachai

Аннотация

OBJECTIVES: To evaluate the efficacy of nebulized fluticasone propionate in the prevention of postextubation stridor in children.

DESIGN: Double-blind, placebo-controlled randomized clinical trial.

SETTING: PICU in a tertiary referral center.

PATIENTS: Children 1 month to 15 years old who underwent mechanical ventilation.

INTERVENTIONS: Patients were randomly assigned into two groups after stratification based on age group receiving nebulized fluticasone 1,000 µg or normal saline solution, immediately after extubation. Vital signs and modified Westley score were evaluated for 6 hours after extubation. The primary outcome was the prevalence of postextubation stridor.

MEASUREMENTS AND MAIN RESULTS: One hundred forty-seven intubated children were enrolled into this study. Baseline characteristics between two groups were not different. There was no significant difference in the incidence of postextubation stridor (12/74 [16%] vs 13/73 [18%]; p = 0.797). However, when analyzing the subgroup of emergently intubated children, the fluticasone group had a longer delay median time for the initiation of noninvasive ventilation than the control group (380 [90-585] vs 60 [42-116] min; p = 0.044). The modified Westley scores at 30 and 60 minutes in the control group were significantly higher than the fluticasone group (4 vs 2, p = 0.04; 4.5 vs 0.5, p = 0.02, respectively).

CONCLUSIONS: The single dose of 1,000-µg nebulized fluticasone did not decrease the prevalence of postextubation stridor. However, it might be beneficial in emergently intubated children.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич