MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/ped.14735

Медицинская библиотека · Pediatrics international : official journal of the Japan Pediatric Society · 2021

Furosemide clearance in very preterm neonates early in life: A pilot study using scavenged samples.

Okazaki Kaoru, Fukuoka Noriyasu, Kuboi Toru, Unemoto Jun, Kondo Masatoshi, Kusaka Takashi, Itoh Susumu

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Furosemide is an off-label drug, frequently used as a diuretic in neonates with oliguria and/or edema. Its clearance in preterm neonates is lower than in term neonates or children. We aimed, herein, to clarify furosemide clearance (CL) in very preterm (VP) neonates (<28 weeks' gestation) within the first 2 weeks of life and identify the factors predictive of the pharmacokinetics (PK) parameters, such as CL.

METHODS

Furosemide was administered at 0.5 or 1 mg/kg in a 0.5-h infusion via a syringe pump; blood samples were drawn from an artery or vein after the intravenous injection. The serum furosemide concentration was measured using high-performance liquid chromatography. The PK parameters were then analyzed using Bayesian estimation.

RESULTS

Thirteen blood samples were obtained from 10 VP neonates after intravenous injection. The mean postconceptional age and mean postnatal days at exposure to furosemide were 26.9 weeks and 7.1 days, respectively. The estimated mean CL was 16.5 mL/kg/h. The mean distribution volume (Vd) and elimination half-life (t1/2) were 0.37 L/kg and 15.3 h, respectively. Furosemide CL was negatively associated with serum creatinine (SCr) [CL = 84.2 - 67.1 × SCr (mg/dL)].

CONCLUSIONS

Very preterm neonates within the first 2 weeks of life had a higher CL than subjects in other preterm neonatal studies. The SCr level was the sole parameter influencing furosemide CL and might serve as a good index for furosemide dosing in VP neonates.

Для цитирования: Okazaki Kaoru, Fukuoka Noriyasu, Kuboi Toru, Unemoto Jun, Kondo Masatoshi, Kusaka Takashi, Itoh Susumu. Furosemide clearance in very preterm neonates early in life: A pilot study using scavenged samples.. Pediatrics international : official journal of the Japan Pediatric Society. 2021. DOI: 10.1111/ped.14735.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.