MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmbbm.2020.104027

Медицинская библиотека · Journal of the mechanical behavior of biomedical materials · 2020

Cutting mechanics of wood by beetle larval mandibles.

Kundanati Lakshminath, Chahare Nimesh R, Jaddivada Siddhartha, Karkisaval Abhijith G, Sridhar Rajeev, Pugno Nicola M, Gundiah Namrata

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Wood boring is a feature of several insect species and is a major cause of severe and irreparable damage to trees. Adult females typically deposit their eggs on the stem surface under bark scales. The emerging hatchlings live within wood during their larval phase, avoiding possible predation, whilst continually boring and tunneling through wood until pupation. A study of wood boring by insects offers unique insights into the bioengineering principles that drive evolutionary adaptations. We show that larval mandibles of the coffee wood stem borer beetle (Xylotrechus quadripes: Cerambycidae) have a highly sharp cusp edge to initiate fractures in Arabica wood and a suitable shape to generate small wood chips that are suitable for digestion. Cuticle hardness at the tip is significantly enhanced through zinc-enrichment. A hollow architecture significantly reduces bending stresses at the mandibular base without compromising the structural integrity. Finite element model of the mandible showed highest stresses in the tip region; these decreased to significantly lower values at the start of the hollow section. A scaling model based on a fracture mechanics framework shows the importance of the mandible shape in generating optimal chip sizes. These findings contain general principles in tool design and put in focus interactions of insects and their woody hosts.

Для цитирования: Kundanati Lakshminath, Chahare Nimesh R, Jaddivada Siddhartha, Karkisaval Abhijith G, Sridhar Rajeev, Pugno Nicola M, Gundiah Namrata. Cutting mechanics of wood by beetle larval mandibles.. Journal of the mechanical behavior of biomedical materials. 2020. DOI: 10.1016/j.jmbbm.2020.104027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.